TY - JOUR
T1 - Utility of Invasive Electrophysiology Studies in Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation
AU - Rogers, Toby
AU - Devraj, Mithun
AU - Thomaides, Athanasios
AU - Steinvil, Arie
AU - Lipinski, Michael J.
AU - Buchanan, Kyle D.
AU - Alraies, M. Chadi
AU - Koifman, Edward
AU - Gai, Jiaxiang
AU - Torguson, Rebecca
AU - Okubagzi, Petros
AU - Ben-Dor, Itsik
AU - Pichard, Augusto D.
AU - Satler, Lowell F.
AU - Waksman, Ron
N1 - Publisher Copyright:
© 2018 Elsevier Inc.
PY - 2018/6/1
Y1 - 2018/6/1
N2 - Permanent pacemaker (PPM) implantation remains common after transcatheter aortic valve implantation (TAVI). Invasive electrophysiology studies (EPSs) may reduce PPM implantation rates by identifying patients who do not require long-term pacing. At our institution, a new strategy in which patients with equivocal indications for pacing underwent EPSs to determine the need for PPM implantation was adopted. We compared baseline demographics, TAVI procedural details, and outcomes in patients without any conduction disturbance after TAVI, patients with new PPM implantation, and patients with EPS ± new PPM implantation. After exclusion for preexisting PPMs, of a total of 614 consecutive TAVI patients, 117 (19.1%) required new PPM implantation for unequivocal pacing indications, and 95 (15.5%) underwent EPSs. Of those patients who underwent EPSs, 28 (29.5%) required PPM implantation and 67 (70.5%) did not. The overall rate of new PPM implantation was higher for self-expanding versus balloon-expandable valves (34.0% vs 19.9%, p = 0.0011). PPM implantation increased intensive care and hospital length of stay compared with patients without any conduction disturbance (10.7 ± 8.3 vs 8.5 ± 6.4 days, p = 0.003). A negative EPS did not prolong length of stay. There were no significant differences in 30-day and 1-year mortality between groups. In conclusion, among TAVI patients with new-onset conduction disturbance, EPS is a safe strategy to identify those who require PPM implantation and those in whom PPMs can be avoided.
AB - Permanent pacemaker (PPM) implantation remains common after transcatheter aortic valve implantation (TAVI). Invasive electrophysiology studies (EPSs) may reduce PPM implantation rates by identifying patients who do not require long-term pacing. At our institution, a new strategy in which patients with equivocal indications for pacing underwent EPSs to determine the need for PPM implantation was adopted. We compared baseline demographics, TAVI procedural details, and outcomes in patients without any conduction disturbance after TAVI, patients with new PPM implantation, and patients with EPS ± new PPM implantation. After exclusion for preexisting PPMs, of a total of 614 consecutive TAVI patients, 117 (19.1%) required new PPM implantation for unequivocal pacing indications, and 95 (15.5%) underwent EPSs. Of those patients who underwent EPSs, 28 (29.5%) required PPM implantation and 67 (70.5%) did not. The overall rate of new PPM implantation was higher for self-expanding versus balloon-expandable valves (34.0% vs 19.9%, p = 0.0011). PPM implantation increased intensive care and hospital length of stay compared with patients without any conduction disturbance (10.7 ± 8.3 vs 8.5 ± 6.4 days, p = 0.003). A negative EPS did not prolong length of stay. There were no significant differences in 30-day and 1-year mortality between groups. In conclusion, among TAVI patients with new-onset conduction disturbance, EPS is a safe strategy to identify those who require PPM implantation and those in whom PPMs can be avoided.
UR - http://www.scopus.com/inward/record.url?scp=85044276170&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2018.02.015
DO - 10.1016/j.amjcard.2018.02.015
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 29598854
AN - SCOPUS:85044276170
SN - 0002-9149
VL - 121
SP - 1351
EP - 1357
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 11
ER -