TY - JOUR
T1 - Use of Thermoplastic Rings Following Venting of Flexor Tendon Pulleys
T2 - A Biomechanical Analysis
AU - Kadar, Assaf
AU - Haddara, Mohammad M.
AU - Fan, Stacy
AU - Chinchalkar, Shrikant
AU - Ferreira, Louis M.
AU - Suh, Nina
N1 - Publisher Copyright:
© 2021 American Society for Surgery of the Hand
PY - 2021/6
Y1 - 2021/6
N2 - Purpose: Normal digital flexion relies on flexor tendon pulleys to convert linear muscular force to angular digital motion. However, there is a growing trend to vent them partially during flexor tendon repair. The objective of this study was to examine the effects of a thermoplastic ring, acting as an external pulley, on flexor tendon biomechanics and finger range of motion (ROM) after pulley venting. Methods: We tested 15 cadaveric digits using an in vitro active finger motion simulator. We measured loads induced by flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) as well as joint ROM with sequential sectioning of the A2, A3, and A4 pulleys compared with an intact pulley condition. At each stage, external thermoplastic pulley rings were applied snugly over the proximal and middle phalanges to recreate A2 and A4 function, respectively. Results: After complete venting of the A2, A3, and A4 pulleys, proximal interphalangeal joint ROM significantly decreased by 13.4° ± 2.7° and distal interphalangeal joint ROM decreased by 15.8° ± 2.1°. Application of external rings over the proximal and middle phalanx resulted in a residual ROM decrease of 8.3° ± 1.9° at the proximal interphalangeal joint and 7.9° ± 2.1° at the distal interphalangeal joint, nearly restoring ROM. Similarly, complete pulley venting resulted in reduced FDS load by 37% and FDP load by 50% compared with intact pulleys. After application of external rings, loads were restored almost to normal, with a 9% reduction for FDS load and 9% reduction for FDP load compared with intact pulleys. Conclusions: The application of thermoplastic rings acting as external pulleys is an effective, noninvasive, and reproducible approach to restore flexor tendon biomechanics and digit ROM after pulley venting. Clinical relevance: Thermoplastic rings may be a useful therapeutic adjunct in restoring joint ROM and flexor tendon loads after surgical venting of the pulleys.
AB - Purpose: Normal digital flexion relies on flexor tendon pulleys to convert linear muscular force to angular digital motion. However, there is a growing trend to vent them partially during flexor tendon repair. The objective of this study was to examine the effects of a thermoplastic ring, acting as an external pulley, on flexor tendon biomechanics and finger range of motion (ROM) after pulley venting. Methods: We tested 15 cadaveric digits using an in vitro active finger motion simulator. We measured loads induced by flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) as well as joint ROM with sequential sectioning of the A2, A3, and A4 pulleys compared with an intact pulley condition. At each stage, external thermoplastic pulley rings were applied snugly over the proximal and middle phalanges to recreate A2 and A4 function, respectively. Results: After complete venting of the A2, A3, and A4 pulleys, proximal interphalangeal joint ROM significantly decreased by 13.4° ± 2.7° and distal interphalangeal joint ROM decreased by 15.8° ± 2.1°. Application of external rings over the proximal and middle phalanx resulted in a residual ROM decrease of 8.3° ± 1.9° at the proximal interphalangeal joint and 7.9° ± 2.1° at the distal interphalangeal joint, nearly restoring ROM. Similarly, complete pulley venting resulted in reduced FDS load by 37% and FDP load by 50% compared with intact pulleys. After application of external rings, loads were restored almost to normal, with a 9% reduction for FDS load and 9% reduction for FDP load compared with intact pulleys. Conclusions: The application of thermoplastic rings acting as external pulleys is an effective, noninvasive, and reproducible approach to restore flexor tendon biomechanics and digit ROM after pulley venting. Clinical relevance: Thermoplastic rings may be a useful therapeutic adjunct in restoring joint ROM and flexor tendon loads after surgical venting of the pulleys.
KW - Flexor tendon
KW - pulley reconstruction
KW - thermoplastic rings
KW - venting
UR - http://www.scopus.com/inward/record.url?scp=85099502922&partnerID=8YFLogxK
U2 - 10.1016/j.jhsa.2020.11.003
DO - 10.1016/j.jhsa.2020.11.003
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 33357985
AN - SCOPUS:85099502922
SN - 0363-5023
VL - 46
SP - 485
EP - 492
JO - Journal of Hand Surgery
JF - Journal of Hand Surgery
IS - 6
ER -