Unacceptable Cosmesis in a Protocol Investigating Intensity-Modulated Radiotherapy With Active Breathing Control for Accelerated Partial-Breast Irradiation

Reshma Jagsi*, Merav A. Ben-David, Jean M. Moran, Robin B. Marsh, Kent A. Griffith, James A. Hayman, Lori J. Pierce

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

229 Scopus citations

Abstract

Purpose: To report interim cosmetic results and toxicity from a prospective study evaluating accelerated partial-breast irradiation (APBI) administered using a highly conformal external beam approach. Methods and Materials: We enrolled breast cancer patients in an institutional review board-approved prospective study of APBI using beamlet intensity-modulated radiotherapy (IMRT) at deep-inspiration breath-hold. Patients received 38.5 Gy in 3.85 Gy fractions twice daily. Dosimetric parameters in patients who maintained acceptable cosmesis were compared with those in patients developing unacceptable cosmesis in follow-up, using t-tests. Results: Thirty-four patients were enrolled; 2 were excluded from analysis because of fair baseline cosmesis. With a median follow-up of 2.5 years, new unacceptable cosmesis developed in 7 patients, leading to early study closure. We compared patients with new unacceptable cosmesis with those with consistently acceptable cosmesis. Retrospective analysis demonstrated that all but one plan adhered to the dosimetric requirements of the national APBI trial. The mean proportion of a whole-breast reference volume receiving 19.25 Gy (V50) was lower in patients with acceptable cosmesis than in those with unacceptable cosmesis (34.6% vs. 46.1%; p = 0.02). The mean percentage of this reference volume receiving 38.5 Gy (V100) was also lower in patients with acceptable cosmesis (15.5% vs. 23.0%; p = 0.02). Conclusions: The hypofractionated schedule and parameters commonly used for external beam APBI and prescribed by the ongoing national trial may be suboptimal, at least when highly conformal techniques such as IMRT with management of breathing motion are used. The V50 and V100 of the breast reference volume seem correlated with cosmetic outcome, and stricter limits may be appropriate in this setting.

Original languageEnglish
Pages (from-to)71-78
Number of pages8
JournalInternational Journal of Radiation Oncology Biology Physics
Volume76
Issue number1
DOIs
StatePublished - Jan 2010
Externally publishedYes

Keywords

  • Accelerated partial-breast irradiation
  • Breast cancer
  • Cosmesis
  • IMRT
  • Radiotherapy

Fingerprint

Dive into the research topics of 'Unacceptable Cosmesis in a Protocol Investigating Intensity-Modulated Radiotherapy With Active Breathing Control for Accelerated Partial-Breast Irradiation'. Together they form a unique fingerprint.

Cite this