Abstract
We describe a new application of a device called ET5-FLEX (Ethicon) used in laparoscopic surgery. We used this device for complete excision of a broad based villous adenoma at the mid rectum. This procedure was safe with a short and uneventful postoperative course.
Original language | English |
---|---|
Pages (from-to) | 98-99 |
Number of pages | 2 |
Journal | Techniques in Coloproctology |
Volume | 2 |
Issue number | 2 |
State | Published - 1998 |
Externally published | Yes |
Keywords
- Endo-GIA
- Laparoscopic surgery
- Rectal polyps
- Transanal excision