TY - JOUR
T1 - The reliability and validity of a clinical 3D freehand ultrasound system
AU - Cenni, Francesco
AU - Monari, Davide
AU - Desloovere, Kaat
AU - Aertbeliën, Erwin
AU - Schless, Simon Henri
AU - Bruyninckx, Herman
N1 - Publisher Copyright:
© 2016 Elsevier Ireland Ltd
PY - 2016/11/1
Y1 - 2016/11/1
N2 - Background and Objective Acquiring large anatomical volumes in a feasible manner is useful for clinical decision-making. A relatively new technique called 3D freehand ultrasonography is capable of this by combining a conventional 2D ultrasonography system. Currently, a thorough analysis of this technique is lacking, as the analyses are dependent on the software implementation details and the choice of measurement systems. Therefore this study starts by making this implementation available under the form of an open-source software library to perform 3D freehand ultrasonography. Following that, reliability and validity analyses of extracting volumes and lengths will be carried out using two independent motion-tracking systems. Methods A PC-based ultrasonography device and two optical motion-tracking systems were used for data acquisition. An in-house software library called Py3DFreeHandUS was developed to reconstruct (off-line) the corresponding data into one 3D data set. Reliability and validity analyses of the entire experimental set-up were performed by estimating the volumes and lengths of ground truth objects. Ten water-filled balloons and six cross-wires were used. Repeat measurements were also performed by two experienced operators. Results The software library Py3DFreeHandUS is available online, along with the relevant documentation. The reliability analyses showed high intra- and inter-operator intra-class correlation coefficient results for both volumes and lengths. The accuracy analysis revealed a discrepancy in all cases of around 3%, which corresponded to 3 ml and 1 mm for volume and length measurements, respectively. Similar results were found for both of the motion-tracking systems. Conclusions The undertaken analyses for estimating volume and lengths acquired with 3D freehand ultrasonography demonstrated reliable design measurements and suitable performance for applications that do not require sub-mm and -ml accuracy.
AB - Background and Objective Acquiring large anatomical volumes in a feasible manner is useful for clinical decision-making. A relatively new technique called 3D freehand ultrasonography is capable of this by combining a conventional 2D ultrasonography system. Currently, a thorough analysis of this technique is lacking, as the analyses are dependent on the software implementation details and the choice of measurement systems. Therefore this study starts by making this implementation available under the form of an open-source software library to perform 3D freehand ultrasonography. Following that, reliability and validity analyses of extracting volumes and lengths will be carried out using two independent motion-tracking systems. Methods A PC-based ultrasonography device and two optical motion-tracking systems were used for data acquisition. An in-house software library called Py3DFreeHandUS was developed to reconstruct (off-line) the corresponding data into one 3D data set. Reliability and validity analyses of the entire experimental set-up were performed by estimating the volumes and lengths of ground truth objects. Ten water-filled balloons and six cross-wires were used. Repeat measurements were also performed by two experienced operators. Results The software library Py3DFreeHandUS is available online, along with the relevant documentation. The reliability analyses showed high intra- and inter-operator intra-class correlation coefficient results for both volumes and lengths. The accuracy analysis revealed a discrepancy in all cases of around 3%, which corresponded to 3 ml and 1 mm for volume and length measurements, respectively. Similar results were found for both of the motion-tracking systems. Conclusions The undertaken analyses for estimating volume and lengths acquired with 3D freehand ultrasonography demonstrated reliable design measurements and suitable performance for applications that do not require sub-mm and -ml accuracy.
KW - 3D freehand ultrasonography
KW - Open source software
KW - Reliability and validity analysis
KW - Volume and length measurements
UR - http://www.scopus.com/inward/record.url?scp=84986538266&partnerID=8YFLogxK
U2 - 10.1016/j.cmpb.2016.09.001
DO - 10.1016/j.cmpb.2016.09.001
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 27686714
AN - SCOPUS:84986538266
SN - 0169-2607
VL - 136
SP - 179
EP - 187
JO - Computer Methods and Programs in Biomedicine
JF - Computer Methods and Programs in Biomedicine
ER -