TY - JOUR
T1 - The quality of load matching in a direct-coupling photovoltaic system
AU - Applebaum, J.
PY - 1987/12
Y1 - 1987/12
N2 - The quality of load matching in a photovoltaic system determines the quality of system performance and the degree of the solar cells utilization. In a matched system, the operation of the load-line is close to the maximum power-line of the solar cell (SC) generator. Some load-lines inherently exhibit a relatively good matching when they are directly connected to the SC generator; for others, the matching is rather poor, and therefore, requires the inclusion of a maximum-power-point-tracker (MPPT) in the system. This present study deals with the performance analysis of six common types of loads that are directly connected to the SC generator, and defines a factor that describes the quality of matching of the load to the solar cells. The results of the study indicate the compatibility of the different loads when powered by solar cells, and will assist the designer of the photovoltaic system in considering whether to include an MPPT. The quality of load matching is defined here as the ratio of the load input power to the SC generator maximum power as a function of the solar insolation, or as a function of the solar time. The six loads are: an ohmic load, a storage battery, an ohmic load and storage battery, a water electrolyzer, a power conditioner—constant power load, and a dc motor driving volumetric and centrifugal pumps. The results show, for example, that a storage battery with an appropriate operating voltage gives good matching to solar cells, but a dc motor driving a volumetric pump results in poor matching.
AB - The quality of load matching in a photovoltaic system determines the quality of system performance and the degree of the solar cells utilization. In a matched system, the operation of the load-line is close to the maximum power-line of the solar cell (SC) generator. Some load-lines inherently exhibit a relatively good matching when they are directly connected to the SC generator; for others, the matching is rather poor, and therefore, requires the inclusion of a maximum-power-point-tracker (MPPT) in the system. This present study deals with the performance analysis of six common types of loads that are directly connected to the SC generator, and defines a factor that describes the quality of matching of the load to the solar cells. The results of the study indicate the compatibility of the different loads when powered by solar cells, and will assist the designer of the photovoltaic system in considering whether to include an MPPT. The quality of load matching is defined here as the ratio of the load input power to the SC generator maximum power as a function of the solar insolation, or as a function of the solar time. The six loads are: an ohmic load, a storage battery, an ohmic load and storage battery, a water electrolyzer, a power conditioner—constant power load, and a dc motor driving volumetric and centrifugal pumps. The results show, for example, that a storage battery with an appropriate operating voltage gives good matching to solar cells, but a dc motor driving a volumetric pump results in poor matching.
UR - http://www.scopus.com/inward/record.url?scp=0023596157&partnerID=8YFLogxK
U2 - 10.1109/TEC.1987.4765889
DO - 10.1109/TEC.1987.4765889
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:0023596157
SN - 0885-8969
VL - EC-2
SP - 534
EP - 541
JO - IEEE Transactions on Energy Conversion
JF - IEEE Transactions on Energy Conversion
IS - 4
ER -