TY - JOUR
T1 - The Impact of Total Deceleration Area and Fetal Growth on Neonatal Acidemia in Vacuum Extraction Deliveries
AU - Cohen, Gal
AU - Ravid, Dorit
AU - Gnaiem, Nagam
AU - Gluska, Hadar
AU - Schreiber, Hanoch
AU - Haleluya, Noa Leybovitz
AU - Biron-Shental, Tal
AU - Kovo, Michal
AU - Markovitch, Ofer
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/5
Y1 - 2023/5
N2 - We aimed to investigate the correlation between total deceleration area (TDA), neonatal birthweight and neonatal acidemia in vacuum extractions (VEs). This is a retrospective study in a tertiary hospital, including VE performed due to non-reassuring fetal heart rate (NRFHR). Electronic fetal monitoring during the 120 min preceding delivery was interpreted by two obstetricians who were blinded to neonatal outcomes. TDA was calculated as the sum of the area under the curve for each deceleration. Neonatal birthweights were classified as low (<2500 g), normal (2500–3999 g) or macrosomic (>4000 g). A total of 85 VEs were analyzed. Multivariable linear regression, adjusted for gestational age, nulliparity and diabetes mellitus, revealed a negative correlation between TDA in the 60 min preceding delivery and umbilical cord pH. For every 10 K increase in TDA, the cord pH decreased by 0.02 (p = 0.038; 95%CI, −0.05–0.00). The use of the Ventouse-Mityvac cup was associated with a 0.08 decrease in cord pH as compared to the Kiwi OmniCup (95%CI, −0.16–0.00; p = 0.049). Low birthweights, compared to normal birthweights, were not associated with a change in cord pH. To conclude, a significant correlation was found between TDA during the 60 min preceding delivery and cord pH in VE performed due to NRFHR.
AB - We aimed to investigate the correlation between total deceleration area (TDA), neonatal birthweight and neonatal acidemia in vacuum extractions (VEs). This is a retrospective study in a tertiary hospital, including VE performed due to non-reassuring fetal heart rate (NRFHR). Electronic fetal monitoring during the 120 min preceding delivery was interpreted by two obstetricians who were blinded to neonatal outcomes. TDA was calculated as the sum of the area under the curve for each deceleration. Neonatal birthweights were classified as low (<2500 g), normal (2500–3999 g) or macrosomic (>4000 g). A total of 85 VEs were analyzed. Multivariable linear regression, adjusted for gestational age, nulliparity and diabetes mellitus, revealed a negative correlation between TDA in the 60 min preceding delivery and umbilical cord pH. For every 10 K increase in TDA, the cord pH decreased by 0.02 (p = 0.038; 95%CI, −0.05–0.00). The use of the Ventouse-Mityvac cup was associated with a 0.08 decrease in cord pH as compared to the Kiwi OmniCup (95%CI, −0.16–0.00; p = 0.049). Low birthweights, compared to normal birthweights, were not associated with a change in cord pH. To conclude, a significant correlation was found between TDA during the 60 min preceding delivery and cord pH in VE performed due to NRFHR.
KW - total deceleration area and neonatal acidemia
KW - total deceleration area and umbilical cord pH
KW - total deceleration area and vacuum extractions
KW - umbilical cord pH in low birthweights
KW - vacuum extraction in low birthweights
UR - http://www.scopus.com/inward/record.url?scp=85160353579&partnerID=8YFLogxK
U2 - 10.3390/children10050776
DO - 10.3390/children10050776
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 37238325
AN - SCOPUS:85160353579
SN - 2227-9067
VL - 10
JO - Children
JF - Children
IS - 5
M1 - 776
ER -