T1 - The impact of an electronic reminder on the use of alarms after separation from cardiopulmonary bypass
AU - Eden, Arieh
AU - Pizov, Reuven
AU - Toderis, Liat
AU - Kantor, Gareth
AU - Perel, Azriel
PY - 2009/4
Y1 - 2009/4
N2 - INTRODUCTION:: During cardiopulmonary bypass (CPB) monitor alarms are routinely disabled. Failure to reactivate these alarms after CPB may jeopardize patient safety. We have produced an electronic reminder that automatically alerts clinicians to reactivate alarms after CPB and have evaluated the alarm reactivation rate after its implementation. METHODS:: We developed and implemented an algorithm that identifies separation from CPB by the return of pulsatile flow and of mechanical ventilation, and checks alarm status (activated, disabled or silenced). If alarms have not been reactivated after separation from CPB, an electronic reminder appears. Data were collected during three time periods: Stage I (304 patients)-baseline period before implementation of the electronic reminder; Stage II (256 patients)-after implementation; Stage III-(435 patients) after a single educational departmental meeting, at the end of Stage II. Incidence of proper alarm reactivation and the number of electronic reminders per patient were compared among stages. RESULTS:: The rate of alarm reactivation at baseline (Stage I) was 22%, increased to 63% (Stage II), and again to 83% during Stage III (P < 0.001). The spontaneous alarm reactivation rate before the appearance of the electronic reminder on the anesthesia information management system screen increased from 19% at Stage II to 42% at stage III (P < 0.001). CONCLUSION:: Introducing an automatic electronic reminder significantly increased the rate of alarm reactivation after separation from CPB. Real-time computerized decision-support tools can be developed within anesthesia information management system and may be useful for improving safety during anesthesia.
AB - INTRODUCTION:: During cardiopulmonary bypass (CPB) monitor alarms are routinely disabled. Failure to reactivate these alarms after CPB may jeopardize patient safety. We have produced an electronic reminder that automatically alerts clinicians to reactivate alarms after CPB and have evaluated the alarm reactivation rate after its implementation. METHODS:: We developed and implemented an algorithm that identifies separation from CPB by the return of pulsatile flow and of mechanical ventilation, and checks alarm status (activated, disabled or silenced). If alarms have not been reactivated after separation from CPB, an electronic reminder appears. Data were collected during three time periods: Stage I (304 patients)-baseline period before implementation of the electronic reminder; Stage II (256 patients)-after implementation; Stage III-(435 patients) after a single educational departmental meeting, at the end of Stage II. Incidence of proper alarm reactivation and the number of electronic reminders per patient were compared among stages. RESULTS:: The rate of alarm reactivation at baseline (Stage I) was 22%, increased to 63% (Stage II), and again to 83% during Stage III (P < 0.001). The spontaneous alarm reactivation rate before the appearance of the electronic reminder on the anesthesia information management system screen increased from 19% at Stage II to 42% at stage III (P < 0.001). CONCLUSION:: Introducing an automatic electronic reminder significantly increased the rate of alarm reactivation after separation from CPB. Real-time computerized decision-support tools can be developed within anesthesia information management system and may be useful for improving safety during anesthesia.
UR - http://www.scopus.com/inward/record.url?scp=63849309946&partnerID=8YFLogxK
U2 - 10.1213/ane.0b013e3181984ef9
DO - 10.1213/ane.0b013e3181984ef9
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 19299787
AN - SCOPUS:63849309946
VL - 108
SP - 1203
EP - 1208
JO - Anesthesia and Analgesia
JF - Anesthesia and Analgesia
SN - 0003-2999
IS - 4
ER -