The effect of the rotational angle on MR diffusion indices in nerves: Is the rms displacement of the slow-diffusing component a good measure of fiber orientation?

Amnon Bar-Shir, Yoram Cohen*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

In recent years, much effort has been made to increase our ability to infer nerve fiber direction through the use of diffusion MR. The present study examines the effect of the rotational angle (α), i.e. the angle between the diffusion sensitizing gradients and the main axis of the fibers in the nerves, on different NMR indices. The indices examined were the apparent diffusion coefficient (ADC), extracted from low b-values (bmax ≈ 1200 s/mm2), and the root mean square (rms) displacement of the fast and the slow-diffusing components extracted from high b-value q-space diffusion MR data. In addition, the effect of both the diffusion time and myelination was evaluated. We found that the most sensitive index to the rotational angle is the rms displacement of the slow-diffusing component extracted from the high b-value q-space diffusion MR experiment. For this component the rms displacement was nearly constant for α values ranging from -10° to +80° (where α = 0° is the z direction), but it changed dramatically when diffusion was measured nearly perpendicular to the nerve fiber direction, i.e., for α = 90 ± 10°. The ADC and the rms displacement of the fast-diffusing component exhibited only gradual changes, with a maximal change at α = 45 ± 15°. The sensitivity of the rms displacement of the slow-diffusing component to the rotational angle was found to be higher at longer diffusion times and in mature fully myelinated nerves. The relevance of these observations for determining the fiber direction is briefly discussed.

Original languageEnglish
Pages (from-to)33-42
Number of pages10
JournalJournal of Magnetic Resonance
Volume190
Issue number1
DOIs
StatePublished - Jan 2008

Funding

FundersFunder number
United States-Israel Binational Science Foundation2003/353
Israel Science Foundation522/03

    Keywords

    • Apparent diffusion coefficient (ADC)
    • Diffusion MRS
    • Fiber direction
    • Nerves
    • q-Space diffusion

    Fingerprint

    Dive into the research topics of 'The effect of the rotational angle on MR diffusion indices in nerves: Is the rms displacement of the slow-diffusing component a good measure of fiber orientation?'. Together they form a unique fingerprint.

    Cite this