TY - JOUR
T1 - The effect of resin coating on the shear punch strength of restorative glass ionomer cements
AU - Pilo, Raphael
AU - Ben-Amar, Ariel
AU - Barnea, Anna
AU - Blasbalg, Yaron
AU - Levartovsky, Shifra
N1 - Publisher Copyright:
© 2016, Springer-Verlag Berlin Heidelberg.
PY - 2017/5/1
Y1 - 2017/5/1
N2 - Objective: The aim of the current study was to examine the shear punch strength (SPS) of high-strength glass ionomer cements (HSGICs) in relation to coating applications and duration of coating. Materials and methods: I—Ninety specimens each of Fuji IX GP Fast (FIX Fast), Ionofil Molar AC (IM), Riva Self Cure (R) and Ketac Molar (KM) were prepared and divided into uncoated and coated groups, sub-divided into three sub-groups and incubated for 24 h, 1 week or 8 weeks (distilled water, 37 °C) before SPS. II—Ninety specimens each of uncoated and coated Fuji IX GP Extra were similarly prepared, divided into six sub-groups and incubated for 2 h, 24 h, 1 week, 1 month, 2 months or 3 months (artificial saliva, 37 °C) before SPS. Another 90 specimens were coated for 2 h, 24 h, 1 week, 1 month or 2 months, after which the coating was removed. Specimens were re-incubated in artificial saliva until the end of the 3-month period and then subjected to SPS. Results: None of the materials gained extra strength when coated. Uncoated KM, IM (at all times) and FIX Fast (at 24 h) were stronger. Fuji IX GP Extra achieved 11.5 MPa after 2 h, which increased to 56.7 MPa after 24 h. The highest strength after 3 months was achieved when the coating was retained for 2 h (71.7 MPa). Conclusion: A resin coating will not positively affect the SPS of HSGICs. Clinical relevance: There is no need to protect HSGICs from water to gain extra strength unless the coating is retained for 2 h.
AB - Objective: The aim of the current study was to examine the shear punch strength (SPS) of high-strength glass ionomer cements (HSGICs) in relation to coating applications and duration of coating. Materials and methods: I—Ninety specimens each of Fuji IX GP Fast (FIX Fast), Ionofil Molar AC (IM), Riva Self Cure (R) and Ketac Molar (KM) were prepared and divided into uncoated and coated groups, sub-divided into three sub-groups and incubated for 24 h, 1 week or 8 weeks (distilled water, 37 °C) before SPS. II—Ninety specimens each of uncoated and coated Fuji IX GP Extra were similarly prepared, divided into six sub-groups and incubated for 2 h, 24 h, 1 week, 1 month, 2 months or 3 months (artificial saliva, 37 °C) before SPS. Another 90 specimens were coated for 2 h, 24 h, 1 week, 1 month or 2 months, after which the coating was removed. Specimens were re-incubated in artificial saliva until the end of the 3-month period and then subjected to SPS. Results: None of the materials gained extra strength when coated. Uncoated KM, IM (at all times) and FIX Fast (at 24 h) were stronger. Fuji IX GP Extra achieved 11.5 MPa after 2 h, which increased to 56.7 MPa after 24 h. The highest strength after 3 months was achieved when the coating was retained for 2 h (71.7 MPa). Conclusion: A resin coating will not positively affect the SPS of HSGICs. Clinical relevance: There is no need to protect HSGICs from water to gain extra strength unless the coating is retained for 2 h.
KW - Artificial saliva
KW - Auto-cured glass ionomer
KW - Distilled water
KW - Resin coating
KW - Shear punch strength
UR - http://www.scopus.com/inward/record.url?scp=85018516844&partnerID=8YFLogxK
U2 - 10.1007/s00784-016-1862-8
DO - 10.1007/s00784-016-1862-8
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:85018516844
SN - 1432-6981
VL - 21
SP - 1079
EP - 1086
JO - Clinical Oral Investigations
JF - Clinical Oral Investigations
IS - 4
ER -