TY - JOUR
T1 - The effect of one-step vs. two-step impression techniques on long-term accuracy and dimensional stability when the finish line is within the gingival sulcular area
AU - Levartovsky, Shifra
AU - Zalis, Maayan
AU - Pilo, Raphael
AU - Harel, Noga
AU - Ganor, Yehuda
AU - Brosh, Tamar
PY - 2014/2
Y1 - 2014/2
N2 - Purpose: To evaluate the effect of two putty-wash impression techniques on the long-term accuracy and dimensional stability of poly(vinyl siloxane) (PVS) in the gingival sulcus area. Materials and Methods: Impressions were taken from a master cast to simulate molar crown preparation. A space around the abutment served as the gingival sulcus. Fifteen impressions using the one- and two-step impression techniques were taken using Express Regular, Express Fast, and President impression materials with custom trays. Using a Toolmaker's microscope, the long (LD) and short distances (SD) of the abutment and the planar distance between two parallel lines (PL) at the circumference of the cast were taken at 0.5, 2, 24, 48, 72, 96, 120, and 144 hours after mixing. ANOVA was performed, with the discrepancy between the distances of the impressions and the master cast as the dependent variable. Results: The differences when different materials and impression techniques were used were significant (p < 0.001) for LD, SD, and PL, as was the interaction between the material, time, and technique (p < 0.001). SD discrepancies were higher than those of LD for all materials and times. The two-step impression technique was more accurate, with smaller discrepancies than the one-step impression technique. For all materials, the PL discrepancy was deemed acceptable (less than 0.5%) for all tested times. President had higher discrepancies than the other materials. Conclusions: When using the two-step putty-wash impression technique, pouring of the impressions may be postponed up to 30 hours; however, when using the one-step impression technique, pouring should be performed within 2 hours.
AB - Purpose: To evaluate the effect of two putty-wash impression techniques on the long-term accuracy and dimensional stability of poly(vinyl siloxane) (PVS) in the gingival sulcus area. Materials and Methods: Impressions were taken from a master cast to simulate molar crown preparation. A space around the abutment served as the gingival sulcus. Fifteen impressions using the one- and two-step impression techniques were taken using Express Regular, Express Fast, and President impression materials with custom trays. Using a Toolmaker's microscope, the long (LD) and short distances (SD) of the abutment and the planar distance between two parallel lines (PL) at the circumference of the cast were taken at 0.5, 2, 24, 48, 72, 96, 120, and 144 hours after mixing. ANOVA was performed, with the discrepancy between the distances of the impressions and the master cast as the dependent variable. Results: The differences when different materials and impression techniques were used were significant (p < 0.001) for LD, SD, and PL, as was the interaction between the material, time, and technique (p < 0.001). SD discrepancies were higher than those of LD for all materials and times. The two-step impression technique was more accurate, with smaller discrepancies than the one-step impression technique. For all materials, the PL discrepancy was deemed acceptable (less than 0.5%) for all tested times. President had higher discrepancies than the other materials. Conclusions: When using the two-step putty-wash impression technique, pouring of the impressions may be postponed up to 30 hours; however, when using the one-step impression technique, pouring should be performed within 2 hours.
KW - Accuracy
KW - Dimensional stability
KW - Gingival sulcular area
KW - Impression technique
KW - Poly(vinyl siloxane)
UR - http://www.scopus.com/inward/record.url?scp=84894047075&partnerID=8YFLogxK
U2 - 10.1111/jopr.12062
DO - 10.1111/jopr.12062
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 23734561
AN - SCOPUS:84894047075
SN - 1059-941X
VL - 23
SP - 124
EP - 133
JO - Journal of Prosthodontics
JF - Journal of Prosthodontics
IS - 2
ER -