The Coulostatic Method: Analysis of Error and Computation of Parameters

H. Reller, E. Kirowa-Eisner

Research output: Contribution to journalArticlepeer-review

Abstract

Analysis of error has been carried out for the coulostatic method. The optimal time scale for the determination of i0 has been shown to be equal to 2TC. The determination of i0 is based on the computer curve-fitting of a set of points on the transients to the analytical equation of potential decay. The uncertainty in the determination of i0 depends only on the ratio tc/d. Highest accuracy is otbained for Tc/d > 500, where the uncertainty in the determination of i0 is 3.3 times that for the measurement of the potential. Reasonable accuracy can be obtained for values of CAd not less than 0.5. An iteration method for the simultaneous determination of i0 and Cdi has been outlined.

Original languageEnglish
Pages (from-to)1725-1730
Number of pages6
JournalJournal of the Electrochemical Society
Volume127
Issue number8
DOIs
StatePublished - 1980

Keywords

  • computer
  • coulostatic method
  • decay

Fingerprint

Dive into the research topics of 'The Coulostatic Method: Analysis of Error and Computation of Parameters'. Together they form a unique fingerprint.