TY - JOUR
T1 - Testing of platelet deposition on polystyrene surface under flow conditions by the cone and plate(let) analyzer
T2 - Role of platelet activation, fibrinogen and von Willebrand factor
AU - Shenkman, Boris
AU - Savion, Naphtali
AU - Dardik, Rima
AU - Tamarin, Ilya
AU - Varon, David
N1 - Funding Information:
This work was supported by a grant from Deutsche Forschungsansalt fuer Luft and Raumfahrt and the National Council for Research and Development, Israel. The work was partially supported by a grant from the Israeli Ministry of Absorption.
PY - 2000/8/15
Y1 - 2000/8/15
N2 - Recently, we described a method of testing platelet deposition on extracellular matrix under flow conditions. The method was used for assessment of platelet function in various platelet disorders, for monitoring of replacement and anti-platelet therapy. In the present study, we investigated platelet deposition on a polystyrene surface compared with that on extracellular matrix, under defined shear rates, using the original Cone and Plate(let) Analyzer. A correlation of adhesion rate (surface coverage) and aggregate formation (average size) of platelets from normal citrated blood between polystyrene and extracellular matrix was observed. Blocking of von Willebrand factor binding to glycoprotein Ib by a recombinant von Willebrand factor fragment substantially decreased platelet adhesion to both surfaces. Blocking of GPIIb-IIIa by Arg-Gly-Asp-Ser peptide prevented platelet adhesion to the polystyrene while an extensive adhesion of single platelets to extracellular matrix was observed. Furthermore, platelet adhesion to polystyrene but not to extracellular matrix was completely inhibited by platelet inactivation with prostaglandin E1. Platelets from patients with severe von Willebrand disease yielded very low adhesion to both polystyrene and extracellular matrix. The addition of von Willebrand factor to the blood of these patients or pre-coating of polystyrene surface with von Willebrand factor restored the ability of platelets to adhere and aggregate on the surface. Platelets from patients with Glanzmann's thrombasthenia and afibrinogenemia adhered to extracellular matrix (with defective aggregate formation), while they failed to adhere to the polystyrene. Fibrinogen added to afibrinogenemia blood or pre-coating of the polystyrene with fibrinogen restored the ability of platelets to adhere and aggregate on the surface. In conclusion, the polystyrene surface, like extracellular matrix, can be used to assess platelet function disorders taking in account that platelet deposition on polystyrene under flow is absolutely dependent on platelet activation and on the presence of fibrinogen, von Willebrand factor, and their receptors. (C) 2000 Elsevier Science Ltd.
AB - Recently, we described a method of testing platelet deposition on extracellular matrix under flow conditions. The method was used for assessment of platelet function in various platelet disorders, for monitoring of replacement and anti-platelet therapy. In the present study, we investigated platelet deposition on a polystyrene surface compared with that on extracellular matrix, under defined shear rates, using the original Cone and Plate(let) Analyzer. A correlation of adhesion rate (surface coverage) and aggregate formation (average size) of platelets from normal citrated blood between polystyrene and extracellular matrix was observed. Blocking of von Willebrand factor binding to glycoprotein Ib by a recombinant von Willebrand factor fragment substantially decreased platelet adhesion to both surfaces. Blocking of GPIIb-IIIa by Arg-Gly-Asp-Ser peptide prevented platelet adhesion to the polystyrene while an extensive adhesion of single platelets to extracellular matrix was observed. Furthermore, platelet adhesion to polystyrene but not to extracellular matrix was completely inhibited by platelet inactivation with prostaglandin E1. Platelets from patients with severe von Willebrand disease yielded very low adhesion to both polystyrene and extracellular matrix. The addition of von Willebrand factor to the blood of these patients or pre-coating of polystyrene surface with von Willebrand factor restored the ability of platelets to adhere and aggregate on the surface. Platelets from patients with Glanzmann's thrombasthenia and afibrinogenemia adhered to extracellular matrix (with defective aggregate formation), while they failed to adhere to the polystyrene. Fibrinogen added to afibrinogenemia blood or pre-coating of the polystyrene with fibrinogen restored the ability of platelets to adhere and aggregate on the surface. In conclusion, the polystyrene surface, like extracellular matrix, can be used to assess platelet function disorders taking in account that platelet deposition on polystyrene under flow is absolutely dependent on platelet activation and on the presence of fibrinogen, von Willebrand factor, and their receptors. (C) 2000 Elsevier Science Ltd.
KW - Extracellular matrix
KW - Flow device
KW - Platelet adhesion
KW - Platelet aggregation
KW - Polystyrene surface
UR - http://www.scopus.com/inward/record.url?scp=0034663206&partnerID=8YFLogxK
U2 - 10.1016/S0049-3848(00)00255-3
DO - 10.1016/S0049-3848(00)00255-3
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:0034663206
SN - 0049-3848
VL - 99
SP - 353
EP - 361
JO - Thrombosis Research
JF - Thrombosis Research
IS - 4
ER -