Abstract
Two plasma beams of different materials were produced from Ti, Zr, or Nb cathodes in a triple-cathode vacuum arc deposition apparatus. The cathodes were arranged in a circle centered on the system axis. The plasma produced was transported through a straight plasma duct with an axial magnetic field, into a deposition chamber, in which a single Langmuir probe, an array of probes, or a substrate could be mounted 560 mm from the cathode plane. The saturation ion current produced by one cathode, or by the simultaneous operation of two different cathodes, was measured in vacuum and in a 0.13-2.7 Pa nitrogen background. The spatial distribution of the composition of coatings deposited during simultaneous operation of different cathodes in nitrogen was also studied. It was shown that the ion current produced by each single cathode, and by the simultaneous operation of two cathodes, decreased by a factor of 20-100 when the nitrogen pressure was increased from vacuum to P = 2.7 Pa. During simultaneous operation of two cathodes, the ion saturation current was less than the sum of the ion currents produced by each cathode individually when P<0.4 Pa, while the simultaneous ion current was less than the sum of the individual ion currents when P≥0.4 Pa.
Original language | English |
---|---|
Pages | 609-612 |
Number of pages | 4 |
State | Published - 1998 |
Event | Proceedings of the 1998 18th Interantional Symposium on Discharges and Electrical Insulation in Vacuum. Part 1 (of 2) - Eindhoven, Neth Duration: 17 Aug 1998 → 21 Aug 1998 |
Conference
Conference | Proceedings of the 1998 18th Interantional Symposium on Discharges and Electrical Insulation in Vacuum. Part 1 (of 2) |
---|---|
City | Eindhoven, Neth |
Period | 17/08/98 → 21/08/98 |