TY - JOUR
T1 - Super-response to cardiac resynchronization therapy reduces appropriate implantable cardioverter defibrillator therapy
AU - Killu, Ammar M.
AU - Mazo, Anna
AU - Grupper, Avishay
AU - Madhavan, Malini
AU - Webster, Tracy
AU - Brooke, Kelly L.
AU - Hodge, David O.
AU - Asirvatham, Samuel J.
AU - Friedman, Paul A.
AU - Glikson, Michael
AU - Cha, Yong Mei
N1 - Publisher Copyright:
© 2017 The Author(s).
PY - 2018/8/1
Y1 - 2018/8/1
N2 - Aims: To determine the frequency of implantable cardioverter defibrillator (ICD) therapy following cardiac resynchronization therapy (CRT-D) implantation in super and non-super responders and whether greater improvement in left ventricular (LV) function after CRT is associated with a reduced burden in ICD therapy. Methods and results: This is a two-centre, retrospective study between January 2002 and September 2011. Patients were classified as nonsuper responders and super-responders based on the post-CRT ejection fraction (EF) of < 50% and ≥50%, respectively. Of 629 recipients of CRT-D, 37 (5.9%) were super-responders. Implantable cardioverter defibrillator follow-up was available for a mean duration of 6.2 ± 2.7 years. The 5-year rate of antitachycardia pacing (ATP) in super-responders was significantly lower than in non-super responders (2.7% vs. 22.1%, P = 0.004). Super-responders also had a lower 5-year rate of appropriate ICD shock compared with non-super responders (2.7% vs. 14.3%, P = 0.03). On multivariable analysis, factors associated with appropriate ICD therapy (ICD shock/ATP) include male gender (hazard ratio, HR 1.97, 95% confidence interval, 95% CI 1.15-3.35), secondary prevention indication (HR 2.09, 95% CI 1.13-3.85), increased baseline LV end-systolic diameter (HR 1.03 per mm, 95% CI 1.01-1.06) and higher baseline EF (HR 1.03 per %, 95% CI 1.00-1.06) while super-responder status was highly protective (HR 0.13, 95% CI 0.02-0.91). Conclusion: Recipients of CRT-D that normalize their EF have very low rates of ventricular arrhythmias requiring appropriate ICD therapy compared with those that do not.
AB - Aims: To determine the frequency of implantable cardioverter defibrillator (ICD) therapy following cardiac resynchronization therapy (CRT-D) implantation in super and non-super responders and whether greater improvement in left ventricular (LV) function after CRT is associated with a reduced burden in ICD therapy. Methods and results: This is a two-centre, retrospective study between January 2002 and September 2011. Patients were classified as nonsuper responders and super-responders based on the post-CRT ejection fraction (EF) of < 50% and ≥50%, respectively. Of 629 recipients of CRT-D, 37 (5.9%) were super-responders. Implantable cardioverter defibrillator follow-up was available for a mean duration of 6.2 ± 2.7 years. The 5-year rate of antitachycardia pacing (ATP) in super-responders was significantly lower than in non-super responders (2.7% vs. 22.1%, P = 0.004). Super-responders also had a lower 5-year rate of appropriate ICD shock compared with non-super responders (2.7% vs. 14.3%, P = 0.03). On multivariable analysis, factors associated with appropriate ICD therapy (ICD shock/ATP) include male gender (hazard ratio, HR 1.97, 95% confidence interval, 95% CI 1.15-3.35), secondary prevention indication (HR 2.09, 95% CI 1.13-3.85), increased baseline LV end-systolic diameter (HR 1.03 per mm, 95% CI 1.01-1.06) and higher baseline EF (HR 1.03 per %, 95% CI 1.00-1.06) while super-responder status was highly protective (HR 0.13, 95% CI 0.02-0.91). Conclusion: Recipients of CRT-D that normalize their EF have very low rates of ventricular arrhythmias requiring appropriate ICD therapy compared with those that do not.
KW - Cardiac resynchronization
KW - Cardiac resynchronization therapy
KW - Defibrillator
KW - Heart failure
KW - Implantable cardioverterdefibrillator
KW - Mortality
KW - Response
KW - Treatment
UR - http://www.scopus.com/inward/record.url?scp=85046985980&partnerID=8YFLogxK
U2 - 10.1093/europace/eux235
DO - 10.1093/europace/eux235
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:85046985980
SN - 1099-5129
VL - 20
SP - 1303
EP - 1311
JO - Europace
JF - Europace
IS - 8
ER -