T1 - ST-segment deviation following implantable cardioverter defibrillator shocks
T2 - Incidence, timing, and clinical significance
AU - Gurevitz, Osnat
AU - Lipchenca, Igor
AU - Yaacoby, Elad
AU - Segal, Eran
AU - Perel, Azriel
AU - Eldar, Michael
AU - Glikson, Michael
PY - 2002/10/1
Y1 - 2002/10/1
N2 - ST-segment analysis is frequently used during surgical procedures, while ST deviation is considered a sign of myocardial injury. ST deviations were reported following transthoracic and epicardial electrical shocks. The prevalence, timing, and clinical significance of ST-segment deviation following endocardial ICD shocks are discussed in this article. Twenty-eight patients undergoing 125 shock episodes during ICD implantation or testing were included. A 12-lead ECG was recorded at baseline, continuously during the first 3-10 seconds, 1 minute after test shocks, 3-10 seconds and 1 and 5 minutes after each shock given to terminate VF. ST deviation was diagnosed when the ST-segment was displaced ≥ 1 mm in at least one lead compared to baseline. ST-segment deviations were observed after 49 (39%) of all shock episodes in 17 (61%) of patients. ST elevation was observed after 30 (24%) of all shock episodes, and ST depression after 31 (25%). Following 13 shock episodes in seven patients, ST-elevation and depression were observed. ST depressions occurred more frequently after shocks given to terminate VF than after lower energy test shocks (28% vs 18% respectively, P = 0.045). However, there was no significant difference in the prevalence of ST elevations between the lower or higher energy shocks. No adverse clinical events were observed in patients with or without postshock ST-segment deviation. ST-segment deviation following endocardial ICD shocks is a frequent phenomenon, occurring acutely and resolving during the first few minutes postshock. It may have no prognostic implications.
AB - ST-segment analysis is frequently used during surgical procedures, while ST deviation is considered a sign of myocardial injury. ST deviations were reported following transthoracic and epicardial electrical shocks. The prevalence, timing, and clinical significance of ST-segment deviation following endocardial ICD shocks are discussed in this article. Twenty-eight patients undergoing 125 shock episodes during ICD implantation or testing were included. A 12-lead ECG was recorded at baseline, continuously during the first 3-10 seconds, 1 minute after test shocks, 3-10 seconds and 1 and 5 minutes after each shock given to terminate VF. ST deviation was diagnosed when the ST-segment was displaced ≥ 1 mm in at least one lead compared to baseline. ST-segment deviations were observed after 49 (39%) of all shock episodes in 17 (61%) of patients. ST elevation was observed after 30 (24%) of all shock episodes, and ST depression after 31 (25%). Following 13 shock episodes in seven patients, ST-elevation and depression were observed. ST depressions occurred more frequently after shocks given to terminate VF than after lower energy test shocks (28% vs 18% respectively, P = 0.045). However, there was no significant difference in the prevalence of ST elevations between the lower or higher energy shocks. No adverse clinical events were observed in patients with or without postshock ST-segment deviation. ST-segment deviation following endocardial ICD shocks is a frequent phenomenon, occurring acutely and resolving during the first few minutes postshock. It may have no prognostic implications.
KW - Electric countershock
KW - Electrocardiology
KW - Implantable cardioverter defibrillator
KW - ST-segment
UR - http://www.scopus.com/inward/record.url?scp=0036802475&partnerID=8YFLogxK
U2 - 10.1046/j.1460-9592.2002.01429.x
DO - 10.1046/j.1460-9592.2002.01429.x
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:0036802475
SN - 0147-8389
VL - 25
SP - 1429
EP - 1432
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 10
ER -