TY - JOUR
T1 - Spectroscopic performance studies of 4H-SiC detectors for fusion alpha-particle diagnostics
AU - Raja, P. Vigneshwara
AU - Akhtar, Jamil
AU - Rao, C. V.S.
AU - Vala, Sudhirsinh
AU - Abhangi, Mitul
AU - Murty, N. V.L.Narasimha
N1 - Publisher Copyright:
© 2017 Elsevier B.V.
PY - 2017/10/11
Y1 - 2017/10/11
N2 - The spectroscopic performances of Schottky barrier diodes (SBDs) and bulk detectors fabricated on n-type epitaxial 4H-SiC and high-purity semi-insulating (HPSI) 4H-SiC substrates are studied using 241Am alpha-particles. The spectral responses of the SBD detectors reveal a good energy resolution of 55 keV FWHM (∼1%) at −60 V, and ∼90% charge collection efficiency (CCE) at −100 V. The collected signal charge is stable with time in the SBD detectors; hence polarization effects are not noticed, indicating the good crystalline quality of the epitaxial 4H-SiC for detector applications. On the contrary, a poor energy resolution of 675 keV FWHM (12.3%) at −400 V and a maximum CCE of 28% at −500 V are obtained for the bulk detectors. Moreover, the CCE is found to decrease with time after the application of bias voltage implying the polarization phenomenon. Accordingly, the steady-state CCE of the bulk detectors at −500V is decreased to 13% from its initial value. The inferior spectral response of the bulk detectors is possibly due to the charge trapping and polarization effects. Furthermore, the neutron irradiation effects on the α-particle spectral response of the detectors are examined up to a fluence of 1011 n/cm2. To study the reliability of the SBD detectors at higher irradiation levels, the 14.1 MeV neutron irradiation induced changes in the electrical characteristics of the SBD are investigated up to a fluence of 2×1015n/cm2 by device simulations and the probable degradation in the detector response is analyzed. Finally, the possibility of employing 4H-SiC detectors for the fusion alpha-particle diagnostics is discussed.
AB - The spectroscopic performances of Schottky barrier diodes (SBDs) and bulk detectors fabricated on n-type epitaxial 4H-SiC and high-purity semi-insulating (HPSI) 4H-SiC substrates are studied using 241Am alpha-particles. The spectral responses of the SBD detectors reveal a good energy resolution of 55 keV FWHM (∼1%) at −60 V, and ∼90% charge collection efficiency (CCE) at −100 V. The collected signal charge is stable with time in the SBD detectors; hence polarization effects are not noticed, indicating the good crystalline quality of the epitaxial 4H-SiC for detector applications. On the contrary, a poor energy resolution of 675 keV FWHM (12.3%) at −400 V and a maximum CCE of 28% at −500 V are obtained for the bulk detectors. Moreover, the CCE is found to decrease with time after the application of bias voltage implying the polarization phenomenon. Accordingly, the steady-state CCE of the bulk detectors at −500V is decreased to 13% from its initial value. The inferior spectral response of the bulk detectors is possibly due to the charge trapping and polarization effects. Furthermore, the neutron irradiation effects on the α-particle spectral response of the detectors are examined up to a fluence of 1011 n/cm2. To study the reliability of the SBD detectors at higher irradiation levels, the 14.1 MeV neutron irradiation induced changes in the electrical characteristics of the SBD are investigated up to a fluence of 2×1015n/cm2 by device simulations and the probable degradation in the detector response is analyzed. Finally, the possibility of employing 4H-SiC detectors for the fusion alpha-particle diagnostics is discussed.
KW - 4H-silicon carbide
KW - Alpha-particle detector
KW - Charge collection
KW - Device simulation
KW - Plasma diagnostics
KW - Polarization
UR - http://www.scopus.com/inward/record.url?scp=85026193983&partnerID=8YFLogxK
U2 - 10.1016/j.nima.2017.07.017
DO - 10.1016/j.nima.2017.07.017
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:85026193983
SN - 0168-9002
VL - 869
SP - 118
EP - 127
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
ER -