TY - JOUR
T1 - Spectral sensitivity of Bacillus subtilis spores and MS2 coliphage for validation testing of ultraviolet reactors for water disinfection
AU - Mamane-Gravetz, Hadas
AU - Linden, Karl G.
AU - Cabaj, Alexander
AU - Sommer, Regina
PY - 2005/10/15
Y1 - 2005/10/15
N2 - The microbicidal UV fluence under polychromatic radiation from UV lamps is typically measured using the DNA absorbance spectrum as a weighting factor for the relative wavelength effectiveness. However, this DNA-based weighting does not necessarily match the spectral sensitivity of the microorganism being tested. Bacillus subtilis spores are often used for UV reactor validation in Europe, while MS2 coliphage is typically used for validation testing in the United States. These organisms were exposed to quasi-monochromatic UV irradiation across the microbicidal spectrum at wavelengths of 214, 230, 240, 254, 265, 280, and 293 nm. MS2 was three times more sensitive to wavelengths near 214 nm compared to the 254 nm output of low-pressure lamps, while B. subtilis spores were most sensitive to wavelengths around 265 nm. Use of these action spectra, compared to the DNA-based weighting, resulted in differences in the calculated polychromatic UV fluence. Consequently, the action spectrum, which is specific for each microorganism, has implications on the uncertainty of UV fluence determination during validation of reactors with polychromatic UV lamps.
AB - The microbicidal UV fluence under polychromatic radiation from UV lamps is typically measured using the DNA absorbance spectrum as a weighting factor for the relative wavelength effectiveness. However, this DNA-based weighting does not necessarily match the spectral sensitivity of the microorganism being tested. Bacillus subtilis spores are often used for UV reactor validation in Europe, while MS2 coliphage is typically used for validation testing in the United States. These organisms were exposed to quasi-monochromatic UV irradiation across the microbicidal spectrum at wavelengths of 214, 230, 240, 254, 265, 280, and 293 nm. MS2 was three times more sensitive to wavelengths near 214 nm compared to the 254 nm output of low-pressure lamps, while B. subtilis spores were most sensitive to wavelengths around 265 nm. Use of these action spectra, compared to the DNA-based weighting, resulted in differences in the calculated polychromatic UV fluence. Consequently, the action spectrum, which is specific for each microorganism, has implications on the uncertainty of UV fluence determination during validation of reactors with polychromatic UV lamps.
UR - http://www.scopus.com/inward/record.url?scp=26944452387&partnerID=8YFLogxK
U2 - 10.1021/es048446t
DO - 10.1021/es048446t
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:26944452387
SN - 0013-936X
VL - 39
SP - 7845
EP - 7852
JO - Environmental Science and Technology
JF - Environmental Science and Technology
IS - 20