TY - JOUR
T1 - Single-breathhold four-dimensional assessment of left ventricular volumes and function using k-t BLAST after application of extracellular contrast agent at 3 Tesla
AU - Hamdan, Ashraf
AU - Kelle, Sebastian
AU - Schnackenburg, Bernhard
AU - Wellnhofer, Ernst
AU - Fleck, Eckart
AU - Nagel, Eike
PY - 2008/5
Y1 - 2008/5
N2 - Purpose: To prospectively determine the feasibility and accuracy of a four-dimensional (4D) k-space over time broad-use linear acquisition speed-up technique (k-t BLAST) for the evaluation of left ventricular (LV) volumes in comparison to standard multiple-breathhold cine imaging, using a 3.0 Tesla (3T) MR system. Materials and Methods: In 23 subjects, short-axis cine loops completely covering the LV were acquired using conventional turbo gradient echo (GRE) imaging. Immediately after administration of gadobenate dimeglumine, a rapid single-breathhold k-t BLAST 4D dataset with the same coverage was acquired and reconstructed to short-axis views. Quantitative aortic flow measurement for LV stroke volume (LVSV) was used to calibrate both techniques. For GRE and k-t BLAST cine imaging: LV volumes, ejection fraction (EF), and blood-to-myocardium- contrast (BMC) were determined. Results: k-t BLAST and GRE sequences showed a strong correlation for LV volumes and EF (r = 0.97-0.99; P < 0.001). Excellent agreement was also found between the LVSV determined by aortic flow measurements and LVSV assessed using GRE sequence and k-t BLAST sequence. BMC of GRE was similar to that of k-t BLAST cine imaging. Conclusion: The use of the single-breathhold 4D k-t BLAST technique for the assessment of LV volume is feasible and accurate in 3T MRI.
AB - Purpose: To prospectively determine the feasibility and accuracy of a four-dimensional (4D) k-space over time broad-use linear acquisition speed-up technique (k-t BLAST) for the evaluation of left ventricular (LV) volumes in comparison to standard multiple-breathhold cine imaging, using a 3.0 Tesla (3T) MR system. Materials and Methods: In 23 subjects, short-axis cine loops completely covering the LV were acquired using conventional turbo gradient echo (GRE) imaging. Immediately after administration of gadobenate dimeglumine, a rapid single-breathhold k-t BLAST 4D dataset with the same coverage was acquired and reconstructed to short-axis views. Quantitative aortic flow measurement for LV stroke volume (LVSV) was used to calibrate both techniques. For GRE and k-t BLAST cine imaging: LV volumes, ejection fraction (EF), and blood-to-myocardium- contrast (BMC) were determined. Results: k-t BLAST and GRE sequences showed a strong correlation for LV volumes and EF (r = 0.97-0.99; P < 0.001). Excellent agreement was also found between the LVSV determined by aortic flow measurements and LVSV assessed using GRE sequence and k-t BLAST sequence. BMC of GRE was similar to that of k-t BLAST cine imaging. Conclusion: The use of the single-breathhold 4D k-t BLAST technique for the assessment of LV volume is feasible and accurate in 3T MRI.
KW - 3.0 Tesla
KW - 4D MRI
KW - Left ventricular volume
KW - Magnetic resonance imaging
KW - k-t BLAST
UR - http://www.scopus.com/inward/record.url?scp=42949107448&partnerID=8YFLogxK
U2 - 10.1002/jmri.21332
DO - 10.1002/jmri.21332
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 18425828
AN - SCOPUS:42949107448
SN - 1053-1807
VL - 27
SP - 1028
EP - 1036
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 5
ER -