TY - JOUR
T1 - Sequential versus concomitant surgery of glaucoma drainage implant and Boston keratoprosthesis type 1
AU - Patel, Varun
AU - Moster, Marlene R.
AU - Kishfy, Louis
AU - Barkan, Julian
AU - Zhan, Tingting
AU - Raber, Irving M.
AU - Ayres, Brandon D.
AU - Pro, Michael J.
AU - Waisbourd, Michael
N1 - Publisher Copyright:
© 2016 Wichtig Publishing.
PY - 2016/11/1
Y1 - 2016/11/1
N2 - Purpose: To compare sequential versus concomitant surgery of glaucoma drainage implant (GDI) and Boston keratoprosthesis type 1 (KPro). Methods: Patients who received GDI and KPro in the same eye were divided into 2 groups: GDI placement prior to KPro surgery (sequential group) or GDI placement concomitant with KPro surgery (concomitant group). Main outcome measures were GDI failure, defined as intraocular pressure (IOP) >21 mm Hg, less than a 20% IOP reduction from baseline, or IOP <5 mm Hg on 2 consecutive follow-up visits, any reoperation for glaucoma, or loss of light perception; best-corrected visual acuity (BCVA); and surgical complications. Results: Thirty-five eyes were included in the study: 17 in the sequential group and 18 in the concomitant group. The cumulative incidence of failure after 5 years of follow-up was 23.5% in the sequential group and 27.8% in the concomitant group (p = 0.250). Mean BCVA was significantly better in the concomitant group after 6 months, 1 year, 2 years, and at the last follow-up (p<0.05). Both groups had similar rates of complications (p = 1.000). The most frequent complication was GDI erosion, which occurred in 23.5% (n = 4/17) in the sequential group and in 27.8% (n = 5/18) in the concomitant group (p = 1.000). Conclusions: Glaucoma drainage implant placement at the time of KPro surgery had similar cumulative incidence of failure, but significantly favorable visual outcomes, compared to sequential surgeries. The most frequent complication was GDI erosion, occurring in approximately one fourth of the patients.
AB - Purpose: To compare sequential versus concomitant surgery of glaucoma drainage implant (GDI) and Boston keratoprosthesis type 1 (KPro). Methods: Patients who received GDI and KPro in the same eye were divided into 2 groups: GDI placement prior to KPro surgery (sequential group) or GDI placement concomitant with KPro surgery (concomitant group). Main outcome measures were GDI failure, defined as intraocular pressure (IOP) >21 mm Hg, less than a 20% IOP reduction from baseline, or IOP <5 mm Hg on 2 consecutive follow-up visits, any reoperation for glaucoma, or loss of light perception; best-corrected visual acuity (BCVA); and surgical complications. Results: Thirty-five eyes were included in the study: 17 in the sequential group and 18 in the concomitant group. The cumulative incidence of failure after 5 years of follow-up was 23.5% in the sequential group and 27.8% in the concomitant group (p = 0.250). Mean BCVA was significantly better in the concomitant group after 6 months, 1 year, 2 years, and at the last follow-up (p<0.05). Both groups had similar rates of complications (p = 1.000). The most frequent complication was GDI erosion, which occurred in 23.5% (n = 4/17) in the sequential group and in 27.8% (n = 5/18) in the concomitant group (p = 1.000). Conclusions: Glaucoma drainage implant placement at the time of KPro surgery had similar cumulative incidence of failure, but significantly favorable visual outcomes, compared to sequential surgeries. The most frequent complication was GDI erosion, occurring in approximately one fourth of the patients.
KW - Boston keratoprosthesis
KW - Erosion
KW - Glaucoma drainage implant
KW - Intraocular pressure
KW - Visual acuity
UR - http://www.scopus.com/inward/record.url?scp=84994509453&partnerID=8YFLogxK
U2 - 10.5301/ejo.5000794
DO - 10.5301/ejo.5000794
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 27079206
AN - SCOPUS:84994509453
VL - 26
SP - 556
EP - 563
JO - European Journal of Ophthalmology
JF - European Journal of Ophthalmology
SN - 1120-6721
IS - 6
ER -