@article{896be2f9fb634da08938005cb9a57cd9,
title = "Reversible Atrioventricular Conduction Impairment Following Bipolar Nanosecond Electroporation of the Interventricular Septum",
author = "{van Zyl}, Martin and Ladejobi, {Adetola O.} and Tri, {Jason A.} and Yasin, {Omar Z.} and Connolly, {Richard J.} and Danitz, {David J.} and DeSimone, {Christopher V.} and Killu, {Ammar M.} and Elad Maor and Asirvatham, {Samuel J.}",
note = "Funding Information: Funding was provided through benefactor endowment to the Mayo Clinic Department of Cardiovascular Medicine. Dr. Connolly and Mr. David J. Danitz are employed by Pulse Biosciences Inc., the company that manufactured the pulse generator used in this study. Mr. Jason A. Tri and Drs. Desimone, Killu, Maor, and Asirvatham have filed intellectual property relating to ventricular electroporation. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.",
year = "2021",
month = feb,
doi = "10.1016/j.jacep.2020.10.004",
language = "אנגלית",
volume = "7",
pages = "255--257",
journal = "JACC: Clinical Electrophysiology",
issn = "2405-500X",
publisher = "Elsevier USA",
number = "2",
}