TY - JOUR
T1 - Reproducibility and Convergent Validity of the Sitting-Rising Test in People With Multiple Sclerosis
AU - Greenberg, Temima
AU - Soll, Rotem
AU - Dolev, Mark
AU - Kalron, Alon
N1 - Publisher Copyright:
© 2021 American Congress of Rehabilitation Medicine
PY - 2021/8
Y1 - 2021/8
N2 - Objective: To evaluate the test-retest reproducibility and convergent validity of the sitting-rising test (SRT) in people with multiple sclerosis (PwMS). Design: Observational study comprising a test-retest design. Setting: Multiple Sclerosis Center, Rehabilitation Hospital at Sheba Medical Center, Tel-Hashomer, Israel. Participants: A total of 50 PwMS (32 women, 18 men, N=50), mean age 44.8±7.6 years and mean disease duration of 13.8±8.5 years since diagnosis, were enrolled in the study. The median Expanded Disability Status Scale score was 4.5, indicating a mild-moderate neurologic disability. Interventions: Not applicable. Main Outcome Measures: SRT, posturography measures, 10-repetion sit-to-stand test (10STS), timed Up and Go (TUG) test, hand grip strength, strength of hip flexion/extension/abduction, knee flexion/extension, and Fall Status Questionnaire. Results: The intraclass correlation coefficient value for the intrarater test-retest reproducibility (7- to 10-day interval between tests) of the SRT test, was 0.931 (95% confidence interval, 0.796-0.977). Strong correlations were found between the SRT, TUG test (ρ=−0.709), and 10STS (ρ=−0.719), and moderate correlations were found between the SRT and postural control measures (ρ∼0.4). Moderate correlations were found between the SRT and the hip and knee strength (combined) of the weaker limb (ρ=0.344). No differences were found in the SRT score between fallers and nonfallers. Conclusions: The current study supports the convergent validity and test-retest reproducibility of the SRT in PwMS.
AB - Objective: To evaluate the test-retest reproducibility and convergent validity of the sitting-rising test (SRT) in people with multiple sclerosis (PwMS). Design: Observational study comprising a test-retest design. Setting: Multiple Sclerosis Center, Rehabilitation Hospital at Sheba Medical Center, Tel-Hashomer, Israel. Participants: A total of 50 PwMS (32 women, 18 men, N=50), mean age 44.8±7.6 years and mean disease duration of 13.8±8.5 years since diagnosis, were enrolled in the study. The median Expanded Disability Status Scale score was 4.5, indicating a mild-moderate neurologic disability. Interventions: Not applicable. Main Outcome Measures: SRT, posturography measures, 10-repetion sit-to-stand test (10STS), timed Up and Go (TUG) test, hand grip strength, strength of hip flexion/extension/abduction, knee flexion/extension, and Fall Status Questionnaire. Results: The intraclass correlation coefficient value for the intrarater test-retest reproducibility (7- to 10-day interval between tests) of the SRT test, was 0.931 (95% confidence interval, 0.796-0.977). Strong correlations were found between the SRT, TUG test (ρ=−0.709), and 10STS (ρ=−0.719), and moderate correlations were found between the SRT and postural control measures (ρ∼0.4). Moderate correlations were found between the SRT and the hip and knee strength (combined) of the weaker limb (ρ=0.344). No differences were found in the SRT score between fallers and nonfallers. Conclusions: The current study supports the convergent validity and test-retest reproducibility of the SRT in PwMS.
KW - Accidental falls
KW - Multiple sclerosis
KW - Psychometrics
KW - Rehabilitation
UR - http://www.scopus.com/inward/record.url?scp=85102285432&partnerID=8YFLogxK
U2 - 10.1016/j.apmr.2021.01.079
DO - 10.1016/j.apmr.2021.01.079
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 33581135
AN - SCOPUS:85102285432
SN - 0003-9993
VL - 102
SP - 1541
EP - 1546
JO - Archives of Physical Medicine and Rehabilitation
JF - Archives of Physical Medicine and Rehabilitation
IS - 8
ER -