TY - GEN
T1 - Reliability of copper metallization on silicon-dioxide
AU - Shacham-Diamand, Y.
AU - Dedhia, A.
AU - Hoffstetter, D.
AU - Oldham, W. G.
N1 - Publisher Copyright:
© 1991 IEEE.
PY - 1991
Y1 - 1991
N2 - The reliability of copper metallization on silicon-dioxide over single crystalline silicon was studied by capacitance techniques, secondary-ion-mass spectroscopy analysis and Rutherford Back Scattering. The metallization was either evaporated copper or electroless copper deposited in an alkali-free process. The barrier role of a titanium adhesion layer between the copper and the oxide has also been studied. Biasthermal stress (BTS) studies of MOS structures were conducted at 150°C, 250°C, 275°C and 300°C. The biased samples were stressed at electric field of 1MV/cm for a time ranging between 10 minutes for the higher temperatures up to 168 hours at the lower temperatures. The high-frequency capacitance versus voltage (CV) characteristics of the MOS devices change drastically when the copper reaches the Si/SiCU interface. The penetration time of copper through the oxide was characterized as a function of the temperature and was found to increase exponentially with temperature with an activation energy of about 0.85 ± 0.2 eV. Without bias only a small amount of copper penetrates the oxide. SIMS analysis shows that for such samples the surface concentration is in the vicinity of 10 cm" and drops exponentially into the oxide. On the other hand, devices stressed under positive electric field, without a titanium barrier can show orders-of-magnitude higher copper concentration in the oxide. If the Ti adhesion layer thickness exceeds about 5nm, the devices are not affected by the BTS, even at 300C.
AB - The reliability of copper metallization on silicon-dioxide over single crystalline silicon was studied by capacitance techniques, secondary-ion-mass spectroscopy analysis and Rutherford Back Scattering. The metallization was either evaporated copper or electroless copper deposited in an alkali-free process. The barrier role of a titanium adhesion layer between the copper and the oxide has also been studied. Biasthermal stress (BTS) studies of MOS structures were conducted at 150°C, 250°C, 275°C and 300°C. The biased samples were stressed at electric field of 1MV/cm for a time ranging between 10 minutes for the higher temperatures up to 168 hours at the lower temperatures. The high-frequency capacitance versus voltage (CV) characteristics of the MOS devices change drastically when the copper reaches the Si/SiCU interface. The penetration time of copper through the oxide was characterized as a function of the temperature and was found to increase exponentially with temperature with an activation energy of about 0.85 ± 0.2 eV. Without bias only a small amount of copper penetrates the oxide. SIMS analysis shows that for such samples the surface concentration is in the vicinity of 10 cm" and drops exponentially into the oxide. On the other hand, devices stressed under positive electric field, without a titanium barrier can show orders-of-magnitude higher copper concentration in the oxide. If the Ti adhesion layer thickness exceeds about 5nm, the devices are not affected by the BTS, even at 300C.
UR - https://www.scopus.com/pages/publications/84975340255
U2 - 10.1109/VMIC.1991.152973
DO - 10.1109/VMIC.1991.152973
M3 - ???researchoutput.researchoutputtypes.contributiontobookanthology.conference???
AN - SCOPUS:84975340255
T3 - 1991 Proceedings 8th International IEEE VLSI Multilevel Interconnection Conference, VMIC 1991
SP - 109
EP - 115
BT - 1991 Proceedings 8th International IEEE VLSI Multilevel Interconnection Conference, VMIC 1991
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 8th International IEEE VLSI Multilevel Interconnection Conference, VMIC 1991
Y2 - 11 June 1991 through 12 June 1991
ER -