TY - JOUR
T1 - Refractive results with SMILE using lower energy settings in the United States
AU - Liu, Erica T.
AU - Sella, Ruti
AU - Goernert, Phillip
AU - Kim, Kevin
AU - Chen, Henry
AU - Lin, Robert T.
N1 - Publisher Copyright:
Copyright: © 2021 Liu et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2021/10
Y1 - 2021/10
N2 - Purpose To report the visual and refractive results of small incision lenticule extraction (SMILE) with low energy settings in the United States (US) and to evaluate outcomes for low astigmatism treatment. Setting Private clinical practice. Design Retrospective cohort study. Methods This study retrospectively reviewed 462 consecutive eyes that underwent SMILE with lower energy settings. Inclusion criteria included all patients between the ages of 19–39 with myopic astigmatism up to -11.25 diopters (D) spherical equivalent (sphere up to -10.00 D, astigmatism up to -3.00 D), and corrected distance visual acuity of at least 20/25. Eyes with low astigmatism (0.25 D-0.50 D) were also included. Outcome analysis was performed according to the Standard Graphs for Reporting Refractive Surgery at postoperative month (POM) 1, and POM 3–6 when data were available. Results The mean preoperative spherical equivalent treated was -4.96 ± 2.07; at POM 1, 92% of eyes achieved uncorrected visual acuity (UCVA) of 20/20 or better and maintained visual stability throughout the remainder of the study. At last visit, 431 eyes (93%) achieved UCVA of 20/20 or better, and 461 eyes (99.8%) were 20/25 or better. Ninety-seven (21%) eyes gained at least 1 Snellen line of corrected distance visual acuity and no eyes lost 2 or more lines. Almost all eyes (n = 453, 98%) were within 0.5D of target; 85% of eyes with low astigmatism had ≤0.25 D at last visit compared to 80% of eyes with moderate astigmatism. Conclusions SMILE with U.S.-approved low energy settings is safe, predictable, and efficacious and provides patients with a fast visual recovery.
AB - Purpose To report the visual and refractive results of small incision lenticule extraction (SMILE) with low energy settings in the United States (US) and to evaluate outcomes for low astigmatism treatment. Setting Private clinical practice. Design Retrospective cohort study. Methods This study retrospectively reviewed 462 consecutive eyes that underwent SMILE with lower energy settings. Inclusion criteria included all patients between the ages of 19–39 with myopic astigmatism up to -11.25 diopters (D) spherical equivalent (sphere up to -10.00 D, astigmatism up to -3.00 D), and corrected distance visual acuity of at least 20/25. Eyes with low astigmatism (0.25 D-0.50 D) were also included. Outcome analysis was performed according to the Standard Graphs for Reporting Refractive Surgery at postoperative month (POM) 1, and POM 3–6 when data were available. Results The mean preoperative spherical equivalent treated was -4.96 ± 2.07; at POM 1, 92% of eyes achieved uncorrected visual acuity (UCVA) of 20/20 or better and maintained visual stability throughout the remainder of the study. At last visit, 431 eyes (93%) achieved UCVA of 20/20 or better, and 461 eyes (99.8%) were 20/25 or better. Ninety-seven (21%) eyes gained at least 1 Snellen line of corrected distance visual acuity and no eyes lost 2 or more lines. Almost all eyes (n = 453, 98%) were within 0.5D of target; 85% of eyes with low astigmatism had ≤0.25 D at last visit compared to 80% of eyes with moderate astigmatism. Conclusions SMILE with U.S.-approved low energy settings is safe, predictable, and efficacious and provides patients with a fast visual recovery.
UR - http://www.scopus.com/inward/record.url?scp=85117945594&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0258835
DO - 10.1371/journal.pone.0258835
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.systematicreview???
C2 - 34679121
AN - SCOPUS:85117945594
SN - 1932-6203
VL - 16
JO - PLoS ONE
JF - PLoS ONE
IS - 10 October
M1 - e0258835
ER -