Real-World Performance of the MiniMed™ 780G System: First Report of Outcomes from 4120 Users

Julien Da Silva, Giuseppe Lepore, Tadej Battelino, Arcelia Arrieta, Javier Castañeda, Benyamin Grossman, John Shin, Ohad Cohen*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

142 Scopus citations

Abstract

Background: The MiniMed™ 780G system includes an advanced hybrid closed loop (AHCL) algorithm that provides both automated basal and correction bolus insulin delivery. The preliminary performance of the system in real-world settings was evaluated. Methods: Data uploaded from August 2020 to March 2021 by individuals living in Belgium, Finland, Italy, the Netherlands, Qatar, South Africa, Sweden, Switzerland, and the United Kingdom were aggregated and retrospectively analyzed to determine the mean glucose management indicator (GMI), percentage of time spent within (TIR), below (TBR), and above (TAR) glycemic ranges, system use, and insulin consumption in users having ≥10 days of sensor glucose (SG) data after initiating AHCL. The impact of initiating AHCL was evaluated in a subgroup of users also having ≥10 days of SG data, before AHCL initiation. Results: Users (N = 4120) were observed for a mean of 54 ± 32 days. During this time, they spent a mean of 94.1% ± 11.4% of the time in AHCL and achieved a mean GMI of 6.8% ± 0.3%, TIR of 76.2% ± 9.1%, TBR <70 of 2.5% ± 2.1%, and TAR >180 of 21.3% ± 9.4%, after initiating AHCL. There were 77.3% and 79.0% of users who achieved a TIR >70% and a GMI of <7.0%, respectively. Users for whom comparison with pre-AHCL was possible (N = 812) reduced their GMI by 0.4% ± 0.4% (P = 0.005) and increased their TIR by 12.1% ± 10.5% (P < 0.0001), post-AHCL initiation. More users achieved the glycemic treatment goals of GMI <7.0% (37.6% vs. 75.2%, P < 0.0001) and TIR >70% (34.6% vs. 74.9%, P < 0.0001) when compared with pre-AHCL initiation. Conclusion: Most MiniMed 780G system users achieved TIR >70% and GMI <7%, while minimizing hypoglycemia, in a real-world condition.

Original languageEnglish
Pages (from-to)113-119
Number of pages7
JournalDiabetes Technology and Therapeutics
Volume24
Issue number2
DOIs
StatePublished - 1 Feb 2022
Externally publishedYes

Keywords

  • Automated insulin delivery
  • Diabetes
  • Hyperglycemia
  • Hypoglycemia
  • Real-world evidence
  • Time-in-range

Fingerprint

Dive into the research topics of 'Real-World Performance of the MiniMed™ 780G System: First Report of Outcomes from 4120 Users'. Together they form a unique fingerprint.

Cite this