TY - JOUR
T1 - Real-World Performance of the MiniMed™ 780G System
T2 - First Report of Outcomes from 4120 Users
AU - Silva, Julien Da
AU - Lepore, Giuseppe
AU - Battelino, Tadej
AU - Arrieta, Arcelia
AU - Castañeda, Javier
AU - Grossman, Benyamin
AU - Shin, John
AU - Cohen, Ohad
N1 - Publisher Copyright:
© 2022 Julien Da Silva, et al.
PY - 2022/2/1
Y1 - 2022/2/1
N2 - Background: The MiniMed™ 780G system includes an advanced hybrid closed loop (AHCL) algorithm that provides both automated basal and correction bolus insulin delivery. The preliminary performance of the system in real-world settings was evaluated. Methods: Data uploaded from August 2020 to March 2021 by individuals living in Belgium, Finland, Italy, the Netherlands, Qatar, South Africa, Sweden, Switzerland, and the United Kingdom were aggregated and retrospectively analyzed to determine the mean glucose management indicator (GMI), percentage of time spent within (TIR), below (TBR), and above (TAR) glycemic ranges, system use, and insulin consumption in users having ≥10 days of sensor glucose (SG) data after initiating AHCL. The impact of initiating AHCL was evaluated in a subgroup of users also having ≥10 days of SG data, before AHCL initiation. Results: Users (N = 4120) were observed for a mean of 54 ± 32 days. During this time, they spent a mean of 94.1% ± 11.4% of the time in AHCL and achieved a mean GMI of 6.8% ± 0.3%, TIR of 76.2% ± 9.1%, TBR <70 of 2.5% ± 2.1%, and TAR >180 of 21.3% ± 9.4%, after initiating AHCL. There were 77.3% and 79.0% of users who achieved a TIR >70% and a GMI of <7.0%, respectively. Users for whom comparison with pre-AHCL was possible (N = 812) reduced their GMI by 0.4% ± 0.4% (P = 0.005) and increased their TIR by 12.1% ± 10.5% (P < 0.0001), post-AHCL initiation. More users achieved the glycemic treatment goals of GMI <7.0% (37.6% vs. 75.2%, P < 0.0001) and TIR >70% (34.6% vs. 74.9%, P < 0.0001) when compared with pre-AHCL initiation. Conclusion: Most MiniMed 780G system users achieved TIR >70% and GMI <7%, while minimizing hypoglycemia, in a real-world condition.
AB - Background: The MiniMed™ 780G system includes an advanced hybrid closed loop (AHCL) algorithm that provides both automated basal and correction bolus insulin delivery. The preliminary performance of the system in real-world settings was evaluated. Methods: Data uploaded from August 2020 to March 2021 by individuals living in Belgium, Finland, Italy, the Netherlands, Qatar, South Africa, Sweden, Switzerland, and the United Kingdom were aggregated and retrospectively analyzed to determine the mean glucose management indicator (GMI), percentage of time spent within (TIR), below (TBR), and above (TAR) glycemic ranges, system use, and insulin consumption in users having ≥10 days of sensor glucose (SG) data after initiating AHCL. The impact of initiating AHCL was evaluated in a subgroup of users also having ≥10 days of SG data, before AHCL initiation. Results: Users (N = 4120) were observed for a mean of 54 ± 32 days. During this time, they spent a mean of 94.1% ± 11.4% of the time in AHCL and achieved a mean GMI of 6.8% ± 0.3%, TIR of 76.2% ± 9.1%, TBR <70 of 2.5% ± 2.1%, and TAR >180 of 21.3% ± 9.4%, after initiating AHCL. There were 77.3% and 79.0% of users who achieved a TIR >70% and a GMI of <7.0%, respectively. Users for whom comparison with pre-AHCL was possible (N = 812) reduced their GMI by 0.4% ± 0.4% (P = 0.005) and increased their TIR by 12.1% ± 10.5% (P < 0.0001), post-AHCL initiation. More users achieved the glycemic treatment goals of GMI <7.0% (37.6% vs. 75.2%, P < 0.0001) and TIR >70% (34.6% vs. 74.9%, P < 0.0001) when compared with pre-AHCL initiation. Conclusion: Most MiniMed 780G system users achieved TIR >70% and GMI <7%, while minimizing hypoglycemia, in a real-world condition.
KW - Automated insulin delivery
KW - Diabetes
KW - Hyperglycemia
KW - Hypoglycemia
KW - Real-world evidence
KW - Time-in-range
UR - http://www.scopus.com/inward/record.url?scp=85121146059&partnerID=8YFLogxK
U2 - 10.1089/dia.2021.0203
DO - 10.1089/dia.2021.0203
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 34524003
AN - SCOPUS:85121146059
SN - 1520-9156
VL - 24
SP - 113
EP - 119
JO - Diabetes Technology and Therapeutics
JF - Diabetes Technology and Therapeutics
IS - 2
ER -