TY - JOUR
T1 - Ratiometric Fluorescent Detection of Ultrasound-Regulated ATP Release
T2 - An Ultrasound-Resistant Cu,N-Doped Carbon Nanosphere
AU - Nan, Zhezhu
AU - Liu, Hengyu
AU - Shi, Linrong
AU - Zhu, Hongrui
AU - Chen, Junjie
AU - Ilovitsh, Tali
AU - Wu, Daocheng
AU - Wan, Mingxi
AU - Feng, Yi
N1 - Publisher Copyright:
© 2023 American Chemical Society.
PY - 2023/7/12
Y1 - 2023/7/12
N2 - Focused ultrasound, as a protocol of cancer therapy, might induce extracellular adenosine triphosphate (ATP) release, which could enhance cancer immunotherapy and be monitored as a therapeutic marker. To achieve an ATP-detecting probe resistant to ultrasound irradiation, we constructed a Cu/N-doped carbon nanosphere (CNS), which has two fluorescence (FL) emissions at 438 and 578 nm to detect ultrasound-regulated ATP release. The addition of ATP to Cu/N-doped CNS was conducted to recover the FL intensity at 438 nm, where ATP enhanced the FL intensity probably via intramolecular charge transfer (ICT) primarily and hydrogen-bond-induced emission (HBIE) secondarily. The ratiometric probe was sensitive to detect micro ATP (0.2-0.6 μM) with the limit of detection (LOD) of 0.068 μM. The detection of ultrasound-regulated ATP release by Cu,N-CNS/RhB showed that ATP release was enhanced by the long-pulsed ultrasound irradiation at 1.1 MHz (+37%, p < 0.01) and reduced by the short-pulsed ultrasound irradiation at 5 MHz (−78%, p < 0.001). Moreover, no significant difference in ATP release was detected between the control group and the dual-frequency ultrasound irradiation group (+4%). It is consistent with the results of ATP detection by the ATP-kit. Besides, all-ATP detection was developed to prove that the CNS had ultrasound-resistant properties, which means it could bear the irradiation of focused ultrasound in different patterns and detect all-ATP in real time. In the study, the ultrasound-resistant probe has the advantages of simple preparation, high specificity, low limit of detection, good biocompatibility, and cell imaging ability. It has great potential to act as a multifunctional ultrasound theranostic agent for simultaneous ultrasound therapy, ATP detection, and monitoring.
AB - Focused ultrasound, as a protocol of cancer therapy, might induce extracellular adenosine triphosphate (ATP) release, which could enhance cancer immunotherapy and be monitored as a therapeutic marker. To achieve an ATP-detecting probe resistant to ultrasound irradiation, we constructed a Cu/N-doped carbon nanosphere (CNS), which has two fluorescence (FL) emissions at 438 and 578 nm to detect ultrasound-regulated ATP release. The addition of ATP to Cu/N-doped CNS was conducted to recover the FL intensity at 438 nm, where ATP enhanced the FL intensity probably via intramolecular charge transfer (ICT) primarily and hydrogen-bond-induced emission (HBIE) secondarily. The ratiometric probe was sensitive to detect micro ATP (0.2-0.6 μM) with the limit of detection (LOD) of 0.068 μM. The detection of ultrasound-regulated ATP release by Cu,N-CNS/RhB showed that ATP release was enhanced by the long-pulsed ultrasound irradiation at 1.1 MHz (+37%, p < 0.01) and reduced by the short-pulsed ultrasound irradiation at 5 MHz (−78%, p < 0.001). Moreover, no significant difference in ATP release was detected between the control group and the dual-frequency ultrasound irradiation group (+4%). It is consistent with the results of ATP detection by the ATP-kit. Besides, all-ATP detection was developed to prove that the CNS had ultrasound-resistant properties, which means it could bear the irradiation of focused ultrasound in different patterns and detect all-ATP in real time. In the study, the ultrasound-resistant probe has the advantages of simple preparation, high specificity, low limit of detection, good biocompatibility, and cell imaging ability. It has great potential to act as a multifunctional ultrasound theranostic agent for simultaneous ultrasound therapy, ATP detection, and monitoring.
KW - cell imaging
KW - intramolecular charge transfer
KW - ratiometric fluorescent carbon nanosphere
KW - ultrasound-regulated ATP release
KW - ultrasound-resistant probe
UR - http://www.scopus.com/inward/record.url?scp=85164435372&partnerID=8YFLogxK
U2 - 10.1021/acsami.3c05720
DO - 10.1021/acsami.3c05720
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 37365929
AN - SCOPUS:85164435372
SN - 1944-8244
VL - 15
SP - 32732
EP - 32743
JO - ACS Applied Materials and Interfaces
JF - ACS Applied Materials and Interfaces
IS - 27
ER -