T1 - Performance of epitaxial and HPSI 4H-SiC detectors for plasma X-ray imaging systems
AU - Raja, P. V.
AU - Akhtar, J.
AU - Vala, S.
AU - Abhangi, M.
AU - Murty, N. V.L.N.
N1 - Publisher Copyright:
© 2017 IOP Publishing Ltd and Sissa Medialab.
PY - 2017/8/8
Y1 - 2017/8/8
N2 - The room temperature X-ray spectral response of Schottky barrier diodes (SBDs) and bulk detectors on n-type epitaxial 4H-SiC and high-purity semi-insulating (HPSI) 4H-SiC substrates is investigated in the energy range of 30-40 keV for fusion plasma X-ray imaging systems (XIS). The different noise components (in terms of FWHM-equivalent noise energy) of the detector energy resolution are also analyzed. An energy resolution of 3.5 keV FWHM (for 152Eu X-rays), ∼ 90% charge collection efficiency (CCE) at -100 V are obtained with the SBD detectors. The intrinsic detection efficiency of the SBD detectors at 32 keV and 40 keV is found to be 0.42%, and 0.23%, respectively. In SBD detectors, the X-ray produced signal strength is unchanged with time, therefore the polarization phenomenon is not observed. An energy resolution of 11.2 keV FWHM is noted from the 137Cs X-ray spectral response of the bulk detectors. It is found that the X-ray produced signal decreases with time after the bias voltage was applied to the bulk detectors because of the polarization effect; thus CCE and detection efficiency decreases with time. The CCE attained with the bulk detectors at -500 V is not more than 30%. The identified intrinsic efficiency of the bulk detectors is lower than the SBD detectors. Furthermore, to study the reliability the 4H-SiC detectors in a fusion-reactor like environment, 14.1 MeV and 4.5 MeV neutron irradiation effects on the X-ray spectral response of the detectors are analyzed up to a fluence 1011 n/cm2. Based on the present results, the possible application of the 4H-SiC detectors in the fusion XIS is discussed.
AB - The room temperature X-ray spectral response of Schottky barrier diodes (SBDs) and bulk detectors on n-type epitaxial 4H-SiC and high-purity semi-insulating (HPSI) 4H-SiC substrates is investigated in the energy range of 30-40 keV for fusion plasma X-ray imaging systems (XIS). The different noise components (in terms of FWHM-equivalent noise energy) of the detector energy resolution are also analyzed. An energy resolution of 3.5 keV FWHM (for 152Eu X-rays), ∼ 90% charge collection efficiency (CCE) at -100 V are obtained with the SBD detectors. The intrinsic detection efficiency of the SBD detectors at 32 keV and 40 keV is found to be 0.42%, and 0.23%, respectively. In SBD detectors, the X-ray produced signal strength is unchanged with time, therefore the polarization phenomenon is not observed. An energy resolution of 11.2 keV FWHM is noted from the 137Cs X-ray spectral response of the bulk detectors. It is found that the X-ray produced signal decreases with time after the bias voltage was applied to the bulk detectors because of the polarization effect; thus CCE and detection efficiency decreases with time. The CCE attained with the bulk detectors at -500 V is not more than 30%. The identified intrinsic efficiency of the bulk detectors is lower than the SBD detectors. Furthermore, to study the reliability the 4H-SiC detectors in a fusion-reactor like environment, 14.1 MeV and 4.5 MeV neutron irradiation effects on the X-ray spectral response of the detectors are analyzed up to a fluence 1011 n/cm2. Based on the present results, the possible application of the 4H-SiC detectors in the fusion XIS is discussed.
KW - Inspection with neutrons
KW - Plasma diagnostics - interferometry, spectroscopy and imaging
KW - Solid state detectors
KW - X-ray detectors
UR - http://www.scopus.com/inward/record.url?scp=85031001180&partnerID=8YFLogxK
U2 - 10.1088/1748-0221/12/08/P08006
DO - 10.1088/1748-0221/12/08/P08006
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:85031001180
SN - 1748-0221
VL - 12
JO - Journal of Instrumentation
JF - Journal of Instrumentation
IS - 8
M1 - P08006
ER -