O. Benary*, W. Cleland, I. Ferguson, A. Gordeev, H. Gordon, E. Kistenev, P. Kroon, M. Leltchouk, D. Lissauer, H. Ma, D. Makowiecki, A. Maslennikov, S. McCorkle, D. Onoprienko, A. Onuchin, Y. Oren, V. Panin, J. A. Parsons, V. Radeka, L. RogersD. Rahm, S. Rescia, J. Rutherfoord, M. Seman, M. Smith, J. Sondericker, R. Steiner, D. Stephani, E. Stern, I. Stumer, H. Takai, H. Themann, Y. Tikhonov, W. J. Willis

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Test results of a liquid krypton/argon electromagnetic calorimeter with accordion type electrode structure are presented. The test was carried out at the Brookhaven AGS in a negative beam with good electron identification at momenta 5, 10, 15, and 20 GeV/c. Results on energy resolution, linearity, pointing resolution, and muon response are presented. The results are in good agreement with Monte Carlo calculations. The energy resolution of 6.7% E was achieved using liquid krypton and 7.7% E with liquid argon, with a negligible constant term.

Original languageEnglish
Pages (from-to)363-377
Number of pages15
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume344
Issue number2
DOIs
StatePublished - 1 May 1994