Performance characteristics and evaluation of an automated-developed and quantitative, immunochemical, fecal occult blood screening test

Alex Vilkin, Paul Rozen*, Zohar Levi, Amal Waked, Eran Maoz, Shlomo Birkenfeld, Yaron Niv

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

141 Scopus citations

Abstract

OBJECTIVES: Guaiac fecal occult blood colorectal cancer (CRC) screening tests (FOBT) are faulted for low sensitivity and nonspecificity for human hemoglobin (Hb). Automated-developed, immunochemical, human Hb FOBT (I-FOBT) is specific, eliminates diet restrictions, and Hb quantification allows selection of a threshold for colonoscopy. Aims were to determine 1) test reproducibility; 2) test stability; 3) intrapatient daily I-FOBT variation; 4) test sensitivity and specificity for neoplasia in 500 symptomatic/high-risk patients undergoing colonoscopy; and 5) to correlate fecal Hb measurements with findings. METHODS: The desktop instrument OC-Sensor (Eiken, Japan) automatically develops and quantitates 50 tests/h for Hb. Patients prepared three tests, which were quantified and then 1) repeatedly re-examined; 2) stored at 4°C or 20°C or 28°C and repeatedly examined; and 3) fecal Hb levels were correlated with colonoscopic findings. RESULTS: Five I-FOBTs re-examined five times in 1 day had no significant measurement changes. Thirty tests stored for 21 or more days had a decay/day of 0.3%± 0.4 at 4°C (NS), 2.2%± 1.7 at 20°C (NS), and 3.7%± 1.8 at 28°C (p < 0.05). There were intrapatient variations between the three daily I-FOBTs (NS). At the recommended 100 ng Hb/mL threshold, all six cases of CRCs and 20 out of 28 cases of advanced adenomas were detected; evaluated together their sensitivity and specificity were 76.5% and 95.3%. CONCLUSIONS: Desktop, automated-developed, quantitative I-FOBT is now available. Refrigerated OC-Sensor samples are stable for 21 days, easy to prepare and develop and, at the 100 ng Hb/mL threshold, have high sensitivity, specificity, and negative predictive values for significant neoplasia. Suitability for population CRC screening awaits further evaluation.

Original languageEnglish
Pages (from-to)2519-2525
Number of pages7
JournalAmerican Journal of Gastroenterology
Volume100
Issue number11
DOIs
StatePublished - Nov 2005

Fingerprint

Dive into the research topics of 'Performance characteristics and evaluation of an automated-developed and quantitative, immunochemical, fecal occult blood screening test'. Together they form a unique fingerprint.

Cite this