TY - JOUR
T1 - Penile compression clamps
T2 - A model of the internal mechanical state of penile soft tissues
AU - Levy, Ayelet
AU - Fader, Mandy
AU - Bader, Daniel
AU - Gefen, Amit
N1 - Publisher Copyright:
© 2016 Wiley Periodicals, Inc.
PY - 2017/8
Y1 - 2017/8
N2 - Aims: Prostate cancer is the most frequently diagnosed male cancer and urinary incontinence represents a major consequence following surgery. Penile compression clamps (PCCs) which externally occlude the urethra may be used to manage the incontinence. Despite potential complication of PCCs, such as deformation-inflicted tissue damage, to date, there are no reported biomechanical criteria for design of PCCs, in terms of quantitative parameters for evaluating the safety-versus-efficacy of existing or future designs. Methods: We developed a set of computational three-dimensional models of the penis, to which compression was applied using five generic PCC designs. The internal mechanical states of the soft tissues of the penis were then analysed using finite element simulations. Results: Stresses in skin, fat, and tunica albuginea regularly exceeded 10 kPa (75 mmHg). Cuff-type and knurl-type PCCs pose the highest potential risks to tissue health with elevated tissue stresses around the entire penile perimeter (cuff) or urethral stress concentrations (knurl). The soft and contoured PCCs produced the lowest values of these mechanical parameters. Conclusions: The present study identified design characteristics, including envelopment, adaptability, and durability which provide the safest mechanical conditions in the penis and thus minimize the risk of tissue damage while still managing incontinence. Such data should help to design a safer clamp.
AB - Aims: Prostate cancer is the most frequently diagnosed male cancer and urinary incontinence represents a major consequence following surgery. Penile compression clamps (PCCs) which externally occlude the urethra may be used to manage the incontinence. Despite potential complication of PCCs, such as deformation-inflicted tissue damage, to date, there are no reported biomechanical criteria for design of PCCs, in terms of quantitative parameters for evaluating the safety-versus-efficacy of existing or future designs. Methods: We developed a set of computational three-dimensional models of the penis, to which compression was applied using five generic PCC designs. The internal mechanical states of the soft tissues of the penis were then analysed using finite element simulations. Results: Stresses in skin, fat, and tunica albuginea regularly exceeded 10 kPa (75 mmHg). Cuff-type and knurl-type PCCs pose the highest potential risks to tissue health with elevated tissue stresses around the entire penile perimeter (cuff) or urethral stress concentrations (knurl). The soft and contoured PCCs produced the lowest values of these mechanical parameters. Conclusions: The present study identified design characteristics, including envelopment, adaptability, and durability which provide the safest mechanical conditions in the penis and thus minimize the risk of tissue damage while still managing incontinence. Such data should help to design a safer clamp.
KW - biomechanical modeling
KW - finite element simulations
KW - penile clamps
UR - http://www.scopus.com/inward/record.url?scp=85004131191&partnerID=8YFLogxK
U2 - 10.1002/nau.23172
DO - 10.1002/nau.23172
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 27862230
AN - SCOPUS:85004131191
SN - 0733-2467
VL - 36
SP - 1645
EP - 1650
JO - Neurourology and Urodynamics
JF - Neurourology and Urodynamics
IS - 6
ER -