TY - JOUR
T1 - Osteosynthesis of unstable intracapsular femoral neck fracture by dynamic locking plate or screw fixation
T2 - Early results
AU - Thein, Ran
AU - Herman, Amir
AU - Kedem, Paz
AU - Chechik, Aharon
AU - Shazar, Nachshon
PY - 2014/2
Y1 - 2014/2
N2 - Objectives: The purpose of this study was to compare the postoperative radiologic and clinical outcomes of telescopic femur neck screws and small locking plate device (Targon FN) (group 1) with multiple cancellous screws (group 2) for displaced intracapsular femoral neck fractures. Design: Comparison of a prospective collected data to a historical control group (retrospective). Setting: One community teaching hospital. Patients: Seventy-eight patients (group 1, 31; group 2, 47) underwent reduction and internal fixation of displaced intracapsular femoral neck fractures with either Targon FN device or multiple cancellous screws from March 2000 to July 2010. Their mean age was 53.7 years (SD: 16.4), and the mean follow-up period was 28.6 months. Main outcome measures: Treatment failure was considered to be either a nonunion, osteonecrosis, or revision surgery of any type. Treatment was regarded as successful in patients who did not show failure and had at least 1-year follow-up. Results: One patient in group 1 (3.2%) and 22 (46.8%) in group 2 had a nonunion (P = 0.0001). Four (12.9%) group 1 patients and 16 (34.0%) group 2 patients underwent revision surgery (P = 0.036). Four (12.9%) patients in group 1 and 4 (8.5%) group 2 patients had osteonecrosis of the femoral head (P = 0.531). Multivariate logistic regression showed that internal fixation by the fixed-angle fixation device decreased the odds ratio for overall complication by a factor of 0.23, for example, by 77% (P = 0.018). Conclusions: Performing internal fixation by a fixed-angle fixation device decreased nonunion rates and revision rates. It did not affect the rate of osteonecrosis.
AB - Objectives: The purpose of this study was to compare the postoperative radiologic and clinical outcomes of telescopic femur neck screws and small locking plate device (Targon FN) (group 1) with multiple cancellous screws (group 2) for displaced intracapsular femoral neck fractures. Design: Comparison of a prospective collected data to a historical control group (retrospective). Setting: One community teaching hospital. Patients: Seventy-eight patients (group 1, 31; group 2, 47) underwent reduction and internal fixation of displaced intracapsular femoral neck fractures with either Targon FN device or multiple cancellous screws from March 2000 to July 2010. Their mean age was 53.7 years (SD: 16.4), and the mean follow-up period was 28.6 months. Main outcome measures: Treatment failure was considered to be either a nonunion, osteonecrosis, or revision surgery of any type. Treatment was regarded as successful in patients who did not show failure and had at least 1-year follow-up. Results: One patient in group 1 (3.2%) and 22 (46.8%) in group 2 had a nonunion (P = 0.0001). Four (12.9%) group 1 patients and 16 (34.0%) group 2 patients underwent revision surgery (P = 0.036). Four (12.9%) patients in group 1 and 4 (8.5%) group 2 patients had osteonecrosis of the femoral head (P = 0.531). Multivariate logistic regression showed that internal fixation by the fixed-angle fixation device decreased the odds ratio for overall complication by a factor of 0.23, for example, by 77% (P = 0.018). Conclusions: Performing internal fixation by a fixed-angle fixation device decreased nonunion rates and revision rates. It did not affect the rate of osteonecrosis.
KW - hip fracture
KW - internal fixation
KW - unstable intracapsular fracture
UR - http://www.scopus.com/inward/record.url?scp=84894024656&partnerID=8YFLogxK
U2 - 10.1097/BOT.0b013e3182a225fa
DO - 10.1097/BOT.0b013e3182a225fa
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:84894024656
SN - 0890-5339
VL - 28
SP - 70
EP - 76
JO - Journal of Orthopaedic Trauma
JF - Journal of Orthopaedic Trauma
IS - 2
ER -