T1 - Novel method for non-invasive blood pressure measurement from the finger using an optical system based on dynamic light scattering
AU - Bar-Noam, Adi Schejter
AU - Kaminsky, Alexander
AU - Bravo, Albert
AU - Shenkman, Louis
AU - Nacasch, Naomi
AU - Fine, Ilya
N1 - Publisher Copyright:
© SPIE-OSA 2019
PY - 2019
Y1 - 2019
N2 - Self-measurement of blood pressure (BP) is important for monitoring treatment of hypertension, but current instruments are cumbersome and at times also impractical, especially for the older population. Current optical solutions, such as PPG-based technologies that were developed for improving convenience, provide derived measurements that are often inaccurate, particularly for diastolic values. Alternatively, by using dynamic light scattering (DLS) we are able to measure the direct hemodynamic response. We propose a simple physical model that explains the relation between arterial pressure values and the hemodynamic response which is measured from the finger root following changes in externally applied pressure. Based on this model we have developed a small-scaled, optical, mobile device that measures BP at the finger using dynamic light scattering. The apparatus is positioned at the base of the index finger and contains a ring with an inflatable cuff with two miniaturized dynamic light scattering (mDLS) sensors situated distal to the cuff. The cuff is inflated to above systolic pressure, and changes in blood flow (hemodynamics) are measured during cuff deflation. BP measurement is carried out using specially designed algorithms based on hemodynamic indexes and waveform analysis which capture systolic and diastolic points in real-time. Using this apparatus, we measured BP from 69 patients visiting a hypertension outpatient clinic, and a control group of 15 healthy subjects. BP readings were compared with measurements recorded at the arm location with an Omron device used in the clinic. The mean absolute error (MAE) for systolic and diastolic blood pressure was 7.8 and 9 mmHg, respectively at all ranges of BP measured. In conclusion, using Elfi-Tech's innovative technology, it is possible to measure BP accurately at the finger location using a compact, convenient mDLS-based device with high accuracy.
AB - Self-measurement of blood pressure (BP) is important for monitoring treatment of hypertension, but current instruments are cumbersome and at times also impractical, especially for the older population. Current optical solutions, such as PPG-based technologies that were developed for improving convenience, provide derived measurements that are often inaccurate, particularly for diastolic values. Alternatively, by using dynamic light scattering (DLS) we are able to measure the direct hemodynamic response. We propose a simple physical model that explains the relation between arterial pressure values and the hemodynamic response which is measured from the finger root following changes in externally applied pressure. Based on this model we have developed a small-scaled, optical, mobile device that measures BP at the finger using dynamic light scattering. The apparatus is positioned at the base of the index finger and contains a ring with an inflatable cuff with two miniaturized dynamic light scattering (mDLS) sensors situated distal to the cuff. The cuff is inflated to above systolic pressure, and changes in blood flow (hemodynamics) are measured during cuff deflation. BP measurement is carried out using specially designed algorithms based on hemodynamic indexes and waveform analysis which capture systolic and diastolic points in real-time. Using this apparatus, we measured BP from 69 patients visiting a hypertension outpatient clinic, and a control group of 15 healthy subjects. BP readings were compared with measurements recorded at the arm location with an Omron device used in the clinic. The mean absolute error (MAE) for systolic and diastolic blood pressure was 7.8 and 9 mmHg, respectively at all ranges of BP measured. In conclusion, using Elfi-Tech's innovative technology, it is possible to measure BP accurately at the finger location using a compact, convenient mDLS-based device with high accuracy.
KW - Blood pressure
KW - Dynamic light scattering
KW - Finger
KW - MDLS
KW - PPG
KW - Red blood cells
UR - http://www.scopus.com/inward/record.url?scp=85084435570&partnerID=8YFLogxK
U2 - 10.1117/12.2525685
DO - 10.1117/12.2525685
M3 - ???researchoutput.researchoutputtypes.contributiontobookanthology.conference???
AN - SCOPUS:85084435570
T3 - Optics InfoBase Conference Papers
BT - European Conference on Biomedical Optics, ECBO_2019
PB - OSA - The Optical Society
Y2 - 23 June 2019 through 25 June 2019
ER -