TY - JOUR
T1 - Non-contact optical in-vivo sensing of cilia motion by analyzing speckle patterns
AU - Duadi, Doron
AU - Shabairou, Nadav
AU - Primov-Fever, Adi
AU - Zalevsky, Zeev
N1 - Publisher Copyright:
© 2022, The Author(s).
PY - 2022/12
Y1 - 2022/12
N2 - Cilia motion is an indicator of pathological-ciliary function, however current diagnosis relies on biopsies. In this paper, we propose an innovative approach for sensing cilia motility. We present an endoscopic configuration for measuring the motion frequency of cilia in the nasal cavity. The technique is based on temporal tracking of the reflected spatial distribution of defocused speckle patterns while illuminating the cilia with a laser. The setup splits the optical signal into two channels; One imaging channel is for the visualization of the physician and another is, defocusing channel, to capture the speckles. We present in-vivo measurements from healthy subjects undergoing endoscopic examination. We found an average motion frequency of around 7.3 Hz and 9.8 Hz in the antero-posterior nasal mucus (an area rich in cilia), which matches the normal cilia range of 7–16 Hz. Quantitative and precise measurements of cilia vibration will optimize the diagnosis and treatment of pathological-ciliary function. This method is simple, minimally invasive, inexpensive, and promising to distinguish between normal and ciliary dysfunction.
AB - Cilia motion is an indicator of pathological-ciliary function, however current diagnosis relies on biopsies. In this paper, we propose an innovative approach for sensing cilia motility. We present an endoscopic configuration for measuring the motion frequency of cilia in the nasal cavity. The technique is based on temporal tracking of the reflected spatial distribution of defocused speckle patterns while illuminating the cilia with a laser. The setup splits the optical signal into two channels; One imaging channel is for the visualization of the physician and another is, defocusing channel, to capture the speckles. We present in-vivo measurements from healthy subjects undergoing endoscopic examination. We found an average motion frequency of around 7.3 Hz and 9.8 Hz in the antero-posterior nasal mucus (an area rich in cilia), which matches the normal cilia range of 7–16 Hz. Quantitative and precise measurements of cilia vibration will optimize the diagnosis and treatment of pathological-ciliary function. This method is simple, minimally invasive, inexpensive, and promising to distinguish between normal and ciliary dysfunction.
UR - http://www.scopus.com/inward/record.url?scp=85139292508&partnerID=8YFLogxK
U2 - 10.1038/s41598-022-20557-1
DO - 10.1038/s41598-022-20557-1
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 36198733
AN - SCOPUS:85139292508
SN - 2045-2322
VL - 12
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 16614
ER -