Multidetector Computed Tomography in Patients Who Underwent Transcatheter Mitral Edge-to-Edge Repair

Danon Kaewkes, Shunsuke Kagawa, Vivek Patel, Taku Omori, Keita Koseki, Ofir Koren, Sharon Shalom Natanzon, Alon Shechter, Hasan Jilaihawi, Tarun Chakravarty, Mamoo Nakamura, Moody Makar, Takahiro Shiota, Raj Makkar*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

Multidetector computed tomography (MDCT) can provide valuable information for mitral assessment, but its role in transcatheter mitral edge-to-edge repair (TEER) planning has been poorly elucidated. We aimed to compare MDCT with 3-dimensional transesophageal echocardiography (3D-TEE) for TEER preprocedural evaluation. We analyzed the preprocedural MDCT and 3D-TEE of 108 consecutive patients with mitral regurgitation (MR) who underwent MitraClip implantation. The levels of agreement for the etiology and mechanism of MR, mitral calcification, mitral annulus, and mitral valve orifice area (MVOA) measurements were compared between MDCT and 3D-TEE data. Receiver-operating-characteristic curves were generated for mitral annulus area and MVOA using a low mean transmitral pressure gradient at discharge (<5 mm Hg) as the state variable, and the primary outcome of all-cause mortality or rehospitalization for heart failure at 1 year was compared between MDCT's and 3D-TEE's MVOA <4-cm2 cutoff. Good levels of agreement between MDCT and 3D-TEE were observed for determining the etiology (κ = 0.81) and mechanism (κ = 0.62) of MR but not for grading mitral calcification (κ = 0.31 to 0.35). The correlations between MDCT and 3D-TEE measurements were strong for mitral annulus area (r = 0.90) and good for MVOA (r = 0.73). Furthermore, no significant differences in the area under the receiver-operating-characteristic curve to predict low transmitral pressure gradient at discharge or the primary outcome at 1 year were detected between MDCT- and 3D-TEE-derived parameters (all p >0.05). In conclusion, in patients who underwent TEER with MitraClip, a high degree of agreement for comprehensive evaluation of MR and prediction of clinical outcomes between MDCT and 3D-TEE was observed.

Original languageEnglish
Pages (from-to)101-110
Number of pages10
JournalAmerican Journal of Cardiology
Volume208
DOIs
StatePublished - 1 Dec 2023

Keywords

  • computed tomography
  • MitraClip
  • transcatheter edge-to-edge repair
  • transesophageal echocardiography