TY - JOUR
T1 - Monitoring the effect of mild ischemia with a built-in light-emitting diode contact lens electrode and a low-cost custom-made apparatus
AU - Fleischman, A.
AU - Parvari, U.
AU - Oron, Y.
AU - Geyer, O.
PY - 2012/6
Y1 - 2012/6
N2 - Electroretinography (ERG) is widely used in clinical work and research to assess the retinal function. We evaluated an easy to build ERG setup adapted for small animals comprising two contact lens electrodes with a built-in light-emitting diode and a custom-made amplification system. The system's sensitivity was tested by monitoring ERG in albino rat eyes subjected to mild ischemia. Flash ERG was recorded by two contact lens electrodes positioned on the rat's corneas and used alternately as test or reference. The a- and b-wave amplitudes, a-wave latency, b-wave implicit time and oscillatory potentials (OPs) were analyzed. Ischemia was achieved by elevating the intraocular pressure in the eye's anterior chamber. ERG was recorded on post-ischemia (PI) days 1, 1, 3 and 7. Morphological changes were analyzed on hematoxylin/eosin stained 5m sections of control 7d PI retinas. In control eyes, ERG exhibited a pattern similar to a standard recording. Retinas subjected to mild ischemia preserved ordered layered morphology, exhibiting approximately 30% loss of ganglion cells and no changes in gross morphology. By day 3 PI, ischemia caused an increase in the a-wave amplitude (from 34.9 ± 2.7 to 45.4 ± 4.3 V), a decrease in the b-wave amplitude (from 248 ± 13 to 162 ± 8 V), an increase in a-wave latency (from 11.1 ± 0.3 to 17.3 ± 1.4 ms) and b-wave implicit time (from 81.0 ± 1.6 to 90.0 ± 2.5 ms), and attenuation of OPs. The described setup proved sensitive and reliable for evaluating subtle changes in the retinal function in small animals.
AB - Electroretinography (ERG) is widely used in clinical work and research to assess the retinal function. We evaluated an easy to build ERG setup adapted for small animals comprising two contact lens electrodes with a built-in light-emitting diode and a custom-made amplification system. The system's sensitivity was tested by monitoring ERG in albino rat eyes subjected to mild ischemia. Flash ERG was recorded by two contact lens electrodes positioned on the rat's corneas and used alternately as test or reference. The a- and b-wave amplitudes, a-wave latency, b-wave implicit time and oscillatory potentials (OPs) were analyzed. Ischemia was achieved by elevating the intraocular pressure in the eye's anterior chamber. ERG was recorded on post-ischemia (PI) days 1, 1, 3 and 7. Morphological changes were analyzed on hematoxylin/eosin stained 5m sections of control 7d PI retinas. In control eyes, ERG exhibited a pattern similar to a standard recording. Retinas subjected to mild ischemia preserved ordered layered morphology, exhibiting approximately 30% loss of ganglion cells and no changes in gross morphology. By day 3 PI, ischemia caused an increase in the a-wave amplitude (from 34.9 ± 2.7 to 45.4 ± 4.3 V), a decrease in the b-wave amplitude (from 248 ± 13 to 162 ± 8 V), an increase in a-wave latency (from 11.1 ± 0.3 to 17.3 ± 1.4 ms) and b-wave implicit time (from 81.0 ± 1.6 to 90.0 ± 2.5 ms), and attenuation of OPs. The described setup proved sensitive and reliable for evaluating subtle changes in the retinal function in small animals.
KW - contact lens electrode
KW - electroretinogram
KW - light-emitting diode
KW - rat
KW - retinal ischemia
UR - http://www.scopus.com/inward/record.url?scp=84861149868&partnerID=8YFLogxK
U2 - 10.1088/0967-3334/33/6/1053
DO - 10.1088/0967-3334/33/6/1053
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:84861149868
SN - 0967-3334
VL - 33
SP - 1053
EP - 1062
JO - Physiological Measurement
JF - Physiological Measurement
IS - 6
ER -