TY - JOUR
T1 - Mechanical compression effects on the secretion of VWF and IL-8 by cultured human vein endothelium
AU - Weiss, Dar
AU - Avraham, Sharon
AU - Guttlieb, Ruth
AU - Gasner, Lee
AU - Lotman, Alina
AU - Rotman, Oren M.
AU - Einav, Shmuel
N1 - Publisher Copyright:
© 2017 Weiss et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2017/1
Y1 - 2017/1
N2 - Short peripheral catheters are ubiquitous in today's healthcare environment enabling effective delivery of fluids and medications directly into a patient's vasculature. However, complications related to their use, such as short peripheral catheter thrombophlebitis (SPCT), affect up to 80% of hospitalized patients. While indwelling within the vein, the catheters exert prolonged constant pressure upon the endothelium which can trigger inflammation processes. We have developed and studied an in-vitro model of cultured endothelial cells subjected to mechanical compression of modular self-designed weights, and explored their inflammatory response by quantification of two key biomarkers-vWF and IL-8. Evaluation was performed by ELISA immunoassay and processing of vWF-labeled immunofluorescence images. We found that application of weights correspond to 272 Pa yielded increased release of vWF and IL-8 up to 150% and 250% respectively, comparing to the exertion of 136 Pa. Analyses of the immunofluorescence images revealed significantly longer and more extracellular vWF-strings as well as higher intensity stained-pixels in cells exposed to elevated pressures. The release of both factors found to be significantly dependent on the extent of the exerted pressure. The research shed a light on the relationship between induced mechanical compression and the pathogenesis of SPCT. Minimizing, let alone eliminating the contact between the catheter and the vein wall will mitigate the pressure acting on the endothelium, thereby reducing the secretion of inflammatory factors and lessen the incidence of SPCT.
AB - Short peripheral catheters are ubiquitous in today's healthcare environment enabling effective delivery of fluids and medications directly into a patient's vasculature. However, complications related to their use, such as short peripheral catheter thrombophlebitis (SPCT), affect up to 80% of hospitalized patients. While indwelling within the vein, the catheters exert prolonged constant pressure upon the endothelium which can trigger inflammation processes. We have developed and studied an in-vitro model of cultured endothelial cells subjected to mechanical compression of modular self-designed weights, and explored their inflammatory response by quantification of two key biomarkers-vWF and IL-8. Evaluation was performed by ELISA immunoassay and processing of vWF-labeled immunofluorescence images. We found that application of weights correspond to 272 Pa yielded increased release of vWF and IL-8 up to 150% and 250% respectively, comparing to the exertion of 136 Pa. Analyses of the immunofluorescence images revealed significantly longer and more extracellular vWF-strings as well as higher intensity stained-pixels in cells exposed to elevated pressures. The release of both factors found to be significantly dependent on the extent of the exerted pressure. The research shed a light on the relationship between induced mechanical compression and the pathogenesis of SPCT. Minimizing, let alone eliminating the contact between the catheter and the vein wall will mitigate the pressure acting on the endothelium, thereby reducing the secretion of inflammatory factors and lessen the incidence of SPCT.
UR - http://www.scopus.com/inward/record.url?scp=85009413822&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0169752
DO - 10.1371/journal.pone.0169752
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:85009413822
SN - 1932-6203
VL - 12
JO - PLoS ONE
JF - PLoS ONE
IS - 1
M1 - e0169752
ER -