TY - JOUR
T1 - Measuring small compartments with relatively weak gradients by angular double-pulsed-field-gradient NMR
AU - Morozov, Darya
AU - Bar, Leah
AU - Sochen, Nir
AU - Cohen, Yoram
N1 - Funding Information:
We thank V. Krivitsky and Prof. F. Patolsky from the School of Chemistry of Tel Aviv University for SEM measurements. Partial financial support from the US-Israel Bi-National Foundation (BSF, grant number 2009155 ) and the CONNECT project administrated by the European Commission under Framework Package 7 is greatly acknowledged.
PY - 2013/4
Y1 - 2013/4
N2 - NMR diffusion-diffraction patterns observed in compartments in which restricted diffusion occurs are a useful tool for direct extraction of compartment sizes. Such diffusion-diffraction patterns may be observed when the signal intensity E(q,{increment}) is plotted against the wave-vector q (when q=(2π)-1γδG). However, the smaller the compartment sizes are, the higher are the q-values needed to observe such diffractions. Moreover, these q-values should be achieved using short gradient pulses requiring extremely strong gradient systems. The angular double-pulsed-field gradient (d-PFG) NMR methodology has been proposed as a tool to extract compartment sizes using relatively low q-values. In this study, we have used single-PFG (s-PFG) NMR and angular d-PFG NMR to characterize the size of microcapillaries of about 2±1μm in diameter. We found that these microcapillaries are characterized by relatively strong background gradients that completely masked the effects of the microscopic anisotropy (μA) of the sample, resulting in a completely unexpected E(φ) profile in the angular d-PFG NMR experiments. We also show that bipolar angular d-PFG NMR experiments can largely suppress the effect of these background gradients resulting in the expected E(φ) profile from which the compartment dimensions could be obtained with relatively weak gradient pulses. These results demonstrate that the above methodology provides a quick, reliable, non-invasive means for estimating small pore sizes with relatively weak gradients in the presence of large magnetic susceptibility.
AB - NMR diffusion-diffraction patterns observed in compartments in which restricted diffusion occurs are a useful tool for direct extraction of compartment sizes. Such diffusion-diffraction patterns may be observed when the signal intensity E(q,{increment}) is plotted against the wave-vector q (when q=(2π)-1γδG). However, the smaller the compartment sizes are, the higher are the q-values needed to observe such diffractions. Moreover, these q-values should be achieved using short gradient pulses requiring extremely strong gradient systems. The angular double-pulsed-field gradient (d-PFG) NMR methodology has been proposed as a tool to extract compartment sizes using relatively low q-values. In this study, we have used single-PFG (s-PFG) NMR and angular d-PFG NMR to characterize the size of microcapillaries of about 2±1μm in diameter. We found that these microcapillaries are characterized by relatively strong background gradients that completely masked the effects of the microscopic anisotropy (μA) of the sample, resulting in a completely unexpected E(φ) profile in the angular d-PFG NMR experiments. We also show that bipolar angular d-PFG NMR experiments can largely suppress the effect of these background gradients resulting in the expected E(φ) profile from which the compartment dimensions could be obtained with relatively weak gradient pulses. These results demonstrate that the above methodology provides a quick, reliable, non-invasive means for estimating small pore sizes with relatively weak gradients in the presence of large magnetic susceptibility.
KW - Bipolar Gradients
KW - Compartment Size
KW - Diffusion NMR
KW - Double-Pulsed-Field-Gradient (d-PFG)
KW - Microstructure
KW - NMR Spectroscopy
UR - http://www.scopus.com/inward/record.url?scp=84875236825&partnerID=8YFLogxK
U2 - 10.1016/j.mri.2012.08.007
DO - 10.1016/j.mri.2012.08.007
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:84875236825
SN - 0730-725X
VL - 31
SP - 401
EP - 407
JO - Magnetic Resonance Imaging
JF - Magnetic Resonance Imaging
IS - 3
ER -