TY - JOUR
T1 - Measurement of Poisson's ratio by means of a direct tension test on micron-sized specimens
AU - Banks-Sills, Leslie
AU - Hikri, Yael
AU - Krylov, Slava
AU - Fourman, Victor
AU - Gerson, Yuval
AU - Bruck, Hugh A.
N1 - Funding Information:
We thank the Belfer family for their continuing support, as well as Dr. Alexandr Gurevich for his assistance in the Tel Aviv University Micro and Nano Central Characterization and Fabrication Facility. Support received by the US-Israel Education Foundation through a Fulbright Scholar award for H.A. Bruck was greatly appreciated.
PY - 2011/9/10
Y1 - 2011/9/10
N2 - A methodology developed for measuring Young's modulus and the full stress-strain curve on micron-sized specimens was extended here to measure Poisson's ratio. A dog-bone type specimen was used within a small loading machine with a maximum load of 5 N. The specimen was fabricated from single crystal silicon (SC-Si) with the specimen gage and loading direction in the 0 0 1 orientation. A silicon on insulator (SOI) wafer was used with a deep reactive ion etching (DRIE) based process. Geometrical parameters of the initial cross-sectional area of the gage were measured by means of image processing on environmental scanning electron microscope (ESEM) images. The test setup also consists of an optical microscope with a monochromatic camera and a data acquisition system. The strains were obtained through the displacement field which was determined by means of digital image correlation (DIC). A speckle pattern was placed on the specimen gage. SC-Si was chosen to study since it is expected that on both the micro and macro-scales, Young's modulus and Poisson's ratio will have the same value. Hence, the accuracy of the method may be examined. The average value of Young's modulus E = 131.4 2.1 GPa was obtained with the micro-specimens and is consistent with values determined on the macro-scale (E = 130 GPa). The average value of Poisson's ratio on the micro-scale was found as ν = 0.23 0.03 which is lower than the macro-scale value of ν = 0.28. The failure stress was determined to be σf = 1.46 0.10 GPa. Results for Young's modulus reflect the reliability of the methodology which is suitable for characterization of a large variety of materials exploited in micro-devices for both sensing and actuation. The reasons for the low values measured for ν were investigated through emulations of determining the strains. An improvement in the image acquisition system is suggested.
AB - A methodology developed for measuring Young's modulus and the full stress-strain curve on micron-sized specimens was extended here to measure Poisson's ratio. A dog-bone type specimen was used within a small loading machine with a maximum load of 5 N. The specimen was fabricated from single crystal silicon (SC-Si) with the specimen gage and loading direction in the 0 0 1 orientation. A silicon on insulator (SOI) wafer was used with a deep reactive ion etching (DRIE) based process. Geometrical parameters of the initial cross-sectional area of the gage were measured by means of image processing on environmental scanning electron microscope (ESEM) images. The test setup also consists of an optical microscope with a monochromatic camera and a data acquisition system. The strains were obtained through the displacement field which was determined by means of digital image correlation (DIC). A speckle pattern was placed on the specimen gage. SC-Si was chosen to study since it is expected that on both the micro and macro-scales, Young's modulus and Poisson's ratio will have the same value. Hence, the accuracy of the method may be examined. The average value of Young's modulus E = 131.4 2.1 GPa was obtained with the micro-specimens and is consistent with values determined on the macro-scale (E = 130 GPa). The average value of Poisson's ratio on the micro-scale was found as ν = 0.23 0.03 which is lower than the macro-scale value of ν = 0.28. The failure stress was determined to be σf = 1.46 0.10 GPa. Results for Young's modulus reflect the reliability of the methodology which is suitable for characterization of a large variety of materials exploited in micro-devices for both sensing and actuation. The reasons for the low values measured for ν were investigated through emulations of determining the strains. An improvement in the image acquisition system is suggested.
KW - Deep reactive ion etching
KW - Digital image correlation
KW - Dog-bone specimen
KW - Mechanical properties
KW - Micro-specimen
KW - Single crystal silicon
UR - http://www.scopus.com/inward/record.url?scp=79959739935&partnerID=8YFLogxK
U2 - 10.1016/j.sna.2011.04.030
DO - 10.1016/j.sna.2011.04.030
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:79959739935
VL - 169
SP - 98
EP - 114
JO - Sensors and Actuators A: Physical
JF - Sensors and Actuators A: Physical
SN - 0924-4247
IS - 1
ER -