Maximal Bite Force Measured via Digital Bite Force Transducer in Subjects with or without Dental Implants—A Pilot Study

Shifra Levartovsky*, Gitit Peleg, Shlomo Matalon, Igor Tsesis, Eyal Rosen

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

The aims of the current study were as following: (1) to evaluate the maximal bite forces in patients with dental implants versus patients without dental implants, as measured by a digital bite force transducer (GM10); (2) to evaluate the influences of sex, age, and sleep/awake bruxism on the maximal bite forces of the two groups. Forty patients recruited to the study were divided into two groups: test group (“implant”) if they had one or more posterior restored implants and control group (“no‐implant”) without the presence of posterior dental implants. A digital bite fork (GM10) was used to measure the bite forces from three posterior occluding pairs in all participants. Differences in the mean values between the test and control groups and between different sexes were evaluated using one‐way and two‐way ANOVA tests. A cross‐tabulation analysis was conducted to identify a trend line between the groups. There was no significant difference in the maximal bite force between the test and control groups (p = 0.422), but the cross‐tabulation analysis revealed a clear trend of a stronger representation of the “no‐implant” group at higher occlusal forces. A significant difference was detected between the maximal biting forces of male and female subjects (p = 0.030 in the implant group, p = 0.010 in the no‐implant group), regardless of the experimental group. The presence of bruxism and clenching did not influence the bite force values (p = 0.953), and a significant difference was not found between the age groups (p = 0.393). Within the limitations of this study, it may be assumed that there was no significant difference between the maximal bite forces between patients with and without dental implants but that there was a trend line implicating a stronger representation of the “no‐implant” group at higher forces. In addition, the results revealed a significant sex‐related difference in the maximal occlusal force. Further studies with larger sample sizes are warranted.

Original languageEnglish
Article number1544
JournalApplied Sciences (Switzerland)
Volume12
Issue number3
DOIs
StatePublished - 1 Feb 2022

Keywords

  • Bite fork
  • Dental implant
  • Maximal bite force
  • Tooth

Fingerprint

Dive into the research topics of 'Maximal Bite Force Measured via Digital Bite Force Transducer in Subjects with or without Dental Implants—A Pilot Study'. Together they form a unique fingerprint.

Cite this