TY - JOUR
T1 - Limited-angle tomographic phase microscopy utilizing confocal scanning fluorescence microscopy
AU - Guo, Rongli
AU - Barnea, Itay
AU - Shaked, Natan T.
N1 - Publisher Copyright:
© 2021 Optical Society of America
PY - 2021
Y1 - 2021
N2 - We present a multimodal imaging technique, combining tomographic phase microscopy with limited angular projection range and number, and two-channel spinning-disk confocal scanning fluorescence microscopy. This technique allows high-accuracy 3D refractive index (RI) profiling of live cells in spite of the missing projections. The cellular outer shape and its interior organelles measured by the confocal fluorescence imaging not only specify the cell in molecular levels, but also provide the 3D distributions of the whole cell as well as its organelles. We take these additional 3D morphological details as constraints in Gerchberg-Papoulis-based optical diffraction tomography algorithm. We then obtain an accurate 3D RI tomogram, even with a sparse angular range having a small number of perspective projections, otherwise providing low-accuracy RI reconstruction. Then, we obtain both cellular molecular specificity and inner RI values of the cell and its organelles. We compare the reconstructed 3D RI profiles of various samples, demonstrating the superiority of the proposed technique.
AB - We present a multimodal imaging technique, combining tomographic phase microscopy with limited angular projection range and number, and two-channel spinning-disk confocal scanning fluorescence microscopy. This technique allows high-accuracy 3D refractive index (RI) profiling of live cells in spite of the missing projections. The cellular outer shape and its interior organelles measured by the confocal fluorescence imaging not only specify the cell in molecular levels, but also provide the 3D distributions of the whole cell as well as its organelles. We take these additional 3D morphological details as constraints in Gerchberg-Papoulis-based optical diffraction tomography algorithm. We then obtain an accurate 3D RI tomogram, even with a sparse angular range having a small number of perspective projections, otherwise providing low-accuracy RI reconstruction. Then, we obtain both cellular molecular specificity and inner RI values of the cell and its organelles. We compare the reconstructed 3D RI profiles of various samples, demonstrating the superiority of the proposed technique.
UR - http://www.scopus.com/inward/record.url?scp=85103232280&partnerID=8YFLogxK
U2 - 10.1364/BOE.419598
DO - 10.1364/BOE.419598
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 33996204
AN - SCOPUS:85103232280
SN - 2156-7085
VL - 12
SP - 1869
EP - 1881
JO - Biomedical Optics Express
JF - Biomedical Optics Express
IS - 4
ER -