TY - JOUR
T1 - Introducing a true minimally invasive meshless and dissectionless anchoring system for pelvic organ prolapse repair
AU - Tsivian, Masha
AU - Weintraub, Adi Y.
AU - Neuman, Menahem
AU - Tsivian, Alex
N1 - Publisher Copyright:
© 2015, The International Urogynecological Association.
PY - 2016/4/1
Y1 - 2016/4/1
N2 - Introduction and hypothesis: The objective was to demonstrate the biomechanical properties, feasibility, and potential advantages over conventional techniques of this new anchoring device, NeuGuide™. Methods: We evaluated the pull-out forces required to pull the NeuGuide™ anchor elements from a uniform porcine ligament and a cadaver ligament. We also evaluated the function of the NeuGuide™ and the characteristics of the device for the establishment of verification evidence ensuring the reliability and feasibility of the device. We also evaluated the safety and performance of the NeuGuide™ procedure in female cadavers by palpating the sacro-spinous ligament in real time. We assessed the ability to deploy and fixate the anchor to the sacro-spinous ligament and to stitch the sutures from both sides of the vaginal apex to the cervix, without damaging the surrounding structures. Results: All 12 anchors were inserted into the porcine ligament and the cadaver sacro-spinous ligaments successfully (mean pull-out force 34.13 ± 4.32 and 35.68 ± 9.28 respectively). None of the measured forces were below 20 N. No statistically significant difference was noted in the pull-out forces between the porcine and the cadavers (p = 0.60), between the two cadavers (p = 0.19) and between the right and left sacro-spinous ligaments. No abnormalities or malfunctions were noted in the functional performance of the device. Upon laparotomy, dissection of the cadavers revealed that the sacro-spinous ligaments were reached safely with no damage to the surrounding organs and tissues. Conclusions: This novel anchoring device (NeuGuide™) is aimed at facilitating a durable, easy, and short procedure for sacro-spinous ligament fixation with hypothetically fewer operative complications.
AB - Introduction and hypothesis: The objective was to demonstrate the biomechanical properties, feasibility, and potential advantages over conventional techniques of this new anchoring device, NeuGuide™. Methods: We evaluated the pull-out forces required to pull the NeuGuide™ anchor elements from a uniform porcine ligament and a cadaver ligament. We also evaluated the function of the NeuGuide™ and the characteristics of the device for the establishment of verification evidence ensuring the reliability and feasibility of the device. We also evaluated the safety and performance of the NeuGuide™ procedure in female cadavers by palpating the sacro-spinous ligament in real time. We assessed the ability to deploy and fixate the anchor to the sacro-spinous ligament and to stitch the sutures from both sides of the vaginal apex to the cervix, without damaging the surrounding structures. Results: All 12 anchors were inserted into the porcine ligament and the cadaver sacro-spinous ligaments successfully (mean pull-out force 34.13 ± 4.32 and 35.68 ± 9.28 respectively). None of the measured forces were below 20 N. No statistically significant difference was noted in the pull-out forces between the porcine and the cadavers (p = 0.60), between the two cadavers (p = 0.19) and between the right and left sacro-spinous ligaments. No abnormalities or malfunctions were noted in the functional performance of the device. Upon laparotomy, dissection of the cadavers revealed that the sacro-spinous ligaments were reached safely with no damage to the surrounding organs and tissues. Conclusions: This novel anchoring device (NeuGuide™) is aimed at facilitating a durable, easy, and short procedure for sacro-spinous ligament fixation with hypothetically fewer operative complications.
KW - Anchoring device
KW - Biomechanical properties
KW - NeuGuide™
KW - Sacro-spinous ligament fixation
UR - http://www.scopus.com/inward/record.url?scp=84946128482&partnerID=8YFLogxK
U2 - 10.1007/s00192-015-2875-6
DO - 10.1007/s00192-015-2875-6
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 26531297
AN - SCOPUS:84946128482
SN - 0937-3462
VL - 27
SP - 601
EP - 606
JO - International Urogynecology Journal
JF - International Urogynecology Journal
IS - 4
ER -