Intraoperative Assessment of the Stromal Ablation in Photorefractive Keratectomy

Dana Barequet*, Eliya Levinger, Nadav Levinger, Samuel Levinger, Irina S. Barequet

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: To evaluate the difference between planned and measured central ablation depth (CAD) and compare the first and second operated eye in simultaneous bilateral myopic alcohol-assisted PRK. Methods: A retrospective review of patients was performed. Demographic and preoperative data was abstracted. Intraoperative assessment included environmental data, laser-planned algorithm of ablation (L-CAD), and optical coherence pachymetry (OCP) measurements. The true stromal ablation depth (O-CAD) was calculated by subtracting the immediate post-ablation OCP measurement from the OCP measurement before laser ablation. Deviation in pachymetry (DP) between O-CAD and L-CAD was also assessed. Results: The study comprised 140 eyes from 70 consecutive patients. The mean age was 26.91 ± 6.52 years, and 57.1% were females. O-CAD was significantly correlated to preoperative refractive errors and intraoperative laser settings. DP was not correlated to any of the pre- or intraoperative parameters. L-CAD showed a significant underestimation as compared to O-CAD (67.87 ± 25.42 µm and 77.05 ± 30.79 µm, respectively, p < 0.001), which was shown in 74.3% of the cases. A moderate agreement between the two methods was noted, with a mean deviation of 17%. This difference was maintained for each eye individually (p < 0.001). In addition, DP was significantly higher in the first operated eye as compared to the second operated eye (11.97 ± 16.3 µm and 6.38 ± 19.3 µm respectively, p = 0.04). Conclusion: The intraoperative assessment of stromal ablation showed significantly higher central ablation depth values compared to the laser-planned ablation algorithm. The deviation in pachymetry was higher in the first, compared to the second, operated eye. Awareness is warranted as to the discrepancy between preoperative planning and intraoperative assessment.

Original languageEnglish
Article number1901
JournalJournal of Clinical Medicine
Volume13
Issue number7
DOIs
StatePublished - Apr 2024

Keywords

  • central ablation depth
  • optical coherence pachymetry
  • photorefractive keratectomy
  • stromal ablation

Fingerprint

Dive into the research topics of 'Intraoperative Assessment of the Stromal Ablation in Photorefractive Keratectomy'. Together they form a unique fingerprint.

Cite this