T1 - Interscan reproducibility of computer-aided epicardial and thoracic fat measurement from noncontrast cardiac CT
AU - Nakazato, Ryo
AU - Shmilovich, Haim
AU - Tamarappoo, Balaji K.
AU - Cheng, Victor Y.
AU - Slomka, Piotr J.
AU - Berman, Daniel S.
AU - Dey, Damini
N1 - Funding Information:
This study was supported by the National Institutes of Health (NIH) grant number R21EB006829-01A2 (principal investigator: Damini Dey) from the National Institute of Biomedical Imaging and Bioengineering (NIBIB) , and also in part by a grant from the Glazer Foundation ( IRB 6318 ). The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIBIB or the NIH.
PY - 2011/5
Y1 - 2011/5
N2 - Background: Epicardial fat volume (EFV) measured from noncontrast CT is associated with coronary atherosclerosis and increased risk of major adverse cardiovascular events. Interscan reproducibility of EFV quantification from noncontrast CT has not been reported. Objective: We evaluated the interscan (intrascanner and interscanner) reproducibility of EFV and thoracic fat volume (TFV) measurements from noncontrast CT. Methods: We studied 25 consecutive patients who were scanned twice with 4-slice multidetector CT (MDCT), with 120 kVp, 2.5-mm slice thickness (intrascanner) and 23 consecutive patients who were scanned with MDCT and electron beam CT (EBCT) with 3-mm slice thickness (interscanner). For each scan, EFV and TFV were measured from user-defined range of CT slices covering the heart by experienced imaging cardiologists. Voxels within -30 to -190 HU within the epicardial contours was quantified as EFV. TFV was quantified within the heart range automatically. Repeatability coefficient (RC), defined as 1.96 × SD of the differences between pairs of repeated measures, was determined. Results: Correlations for interscan measurements of EFV and TFV were high for both intrascanner (MDCT-MDCT) and interscanner (EBCT-MDCT) data (correlation coefficient ≥0.98). RC values were lowest (4.3% for EFV and 5.4% for TFV) for intrascanner same-observer measurement. For intrascanner cross-observer measurement, RC values were 10.7% for EFV and 9.0% for TFV. For interscanner data, RC values ranged from 6.8% to 8.2%. Conclusion: Epicardial and thoracic fat measurements with the use of either MDCT or EBCT are highly reproducible.
AB - Background: Epicardial fat volume (EFV) measured from noncontrast CT is associated with coronary atherosclerosis and increased risk of major adverse cardiovascular events. Interscan reproducibility of EFV quantification from noncontrast CT has not been reported. Objective: We evaluated the interscan (intrascanner and interscanner) reproducibility of EFV and thoracic fat volume (TFV) measurements from noncontrast CT. Methods: We studied 25 consecutive patients who were scanned twice with 4-slice multidetector CT (MDCT), with 120 kVp, 2.5-mm slice thickness (intrascanner) and 23 consecutive patients who were scanned with MDCT and electron beam CT (EBCT) with 3-mm slice thickness (interscanner). For each scan, EFV and TFV were measured from user-defined range of CT slices covering the heart by experienced imaging cardiologists. Voxels within -30 to -190 HU within the epicardial contours was quantified as EFV. TFV was quantified within the heart range automatically. Repeatability coefficient (RC), defined as 1.96 × SD of the differences between pairs of repeated measures, was determined. Results: Correlations for interscan measurements of EFV and TFV were high for both intrascanner (MDCT-MDCT) and interscanner (EBCT-MDCT) data (correlation coefficient ≥0.98). RC values were lowest (4.3% for EFV and 5.4% for TFV) for intrascanner same-observer measurement. For intrascanner cross-observer measurement, RC values were 10.7% for EFV and 9.0% for TFV. For interscanner data, RC values ranged from 6.8% to 8.2%. Conclusion: Epicardial and thoracic fat measurements with the use of either MDCT or EBCT are highly reproducible.
KW - Electron beam CT, EBCT
KW - Epicardial fat
KW - Multidetector CT, MDCT
KW - Noncontrast CT
KW - Reproducibility
KW - Thoracic fat
UR - http://www.scopus.com/inward/record.url?scp=79958248108&partnerID=8YFLogxK
U2 - 10.1016/j.jcct.2011.03.009
DO - 10.1016/j.jcct.2011.03.009
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 21511558
AN - SCOPUS:79958248108
VL - 5
SP - 172
EP - 179
JO - Journal of Cardiovascular Computed Tomography
JF - Journal of Cardiovascular Computed Tomography
SN - 1934-5925
IS - 3
ER -