Internal impedance of nickelcadmium batteries with applications to space

D. Lahav*, J. Appelbaum

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

A study of the internal impedance of a 7 A h, SAFT VO7S4, NiCd battery cycled under low earth orbit conditions at high current rates and low temperatures is presented. The tested battery consist of three cells selected from a group of fifty well matched cells. The study presents a relationship between the battery internal impedance, the state of charge and the operating temperature. This relationship may be used as an indicator for the battery state of charge during missions in space.

Original languageEnglish
Pages (from-to)295-301
Number of pages7
JournalJournal of Power Sources
Volume38
Issue number3
DOIs
StatePublished - May 1992

Fingerprint

Dive into the research topics of 'Internal impedance of nickelcadmium batteries with applications to space'. Together they form a unique fingerprint.