Infrared-Guided Patient Setup for Lung Cancer Patients

Yulia Lyatskaya, Steven James, Joseph H. Killoran, Ricardo Soto, Harvey J. Mamon, Lee Chin, Aaron M. Allen*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Purpose: To evaluate the utility of an infrared-guided patient setup (iGPS) system to reduce the uncertainties in the setup of lung cancer patients. Methods and Materials: A total of 15 patients were setup for lung irradiation using skin tattoos and lateral leveling marks. Daily electronic portal device images and iGPS marker locations were acquired and retrospectively reviewed. The iGPS-based shifts were compared with the daily electronic portal device image shifts using both the central axis iGPS marker and all five iGPS markers. For shift calculation using the five markers, rotational misalignment was included. The level of agreement between the iGPS and portal imaging to evaluate the setup was evaluated as the frequency of the shift difference in the range of 0-5 mm, 5-10 mm, and >10 mm. Results: Data were obtained for 450 treatment sessions for 15 patients. The difference in the isocenter shifts between the weekly vs. daily images was 0-5 mm in 42%, 5-10 mm in 30%, and >10 mm in 10% of the images. The shifts seen using the iGPS data were 0-5 mm in 81%, 5-10 mm in 14%, and >10 mm in 5%. Using only the central axis iGPS marker, the difference between the iGPS and portal images was <5 mm in 77%, 5-10 mm in 16%, and >10 mm in 7% in the left-right direction and 73%, 18%, and 9% in the superoinferior direction, respectively. When all five iGPS markers were used, the disagreements between the iGPS and portal image shifts >10 mm were reduced from 7% to 2% in the left-right direction and 9% to 3% in the superoinferior direction. Larger reductions were also seen (e.g., a reduction from 50% to 0% in 1 patient). Conclusion: The daily iGPS-based shifts correlated well with the daily electronic portal device-based shifts. When patient movement has nonlinear rotational components, a combination of surface markers and portal images might be particularly beneficial to improve the setup for lung cancer patients.

Original languageEnglish
Pages (from-to)1124-1133
Number of pages10
JournalInternational Journal of Radiation Oncology Biology Physics
Volume71
Issue number4
DOIs
StatePublished - 15 Jul 2008
Externally publishedYes

Keywords

  • Infrared markers
  • Lung cancer
  • PTV
  • Planning target volume
  • Radiotherapy

Fingerprint

Dive into the research topics of 'Infrared-Guided Patient Setup for Lung Cancer Patients'. Together they form a unique fingerprint.

Cite this