TY - JOUR
T1 - Influence of the CleaRing intraocular open capsule device on refractive predictability in cataract surgery
AU - Megiddo-Barnir, Elinor
AU - Kleinmann, Guy
N1 - Publisher Copyright:
© 2023 Royal Australian and New Zealand College of Ophthalmologists.
PY - 2023/9/1
Y1 - 2023/9/1
N2 - Background: The marked improvement in cataract surgery and intraocular lens (IOL) quality has led to a decline in posterior capsular opacification (PCO) incidence; however, PCO remains a common complication of cataract surgery. The CleaRing intraocular capsule open device (IOCD) decreases PCO incidence. We aimed to investigate the influence of the CleaRing IOCD on refractive predictability in cataract surgery. Methods: We conducted this prospective pilot study at the Wolfson Medical Center, Holon, Israel. Ten eyes of patients who underwent cataract surgery and insertion of an IOL after IOCD implantation into the capsular bag were included. All patients completed 12 months of follow-up, including refraction, measurement of uncorrected (UDVA) and best-corrected distance visual acuity (CDVA), slit-lamp biomicroscopy, and ultrasound biomicroscopy. Results: All the surgeries were uneventful, with no postoperative complications. The IOL was centred in the device and bag in all cases. The mean prediction error at 1 and 12 months postoperatively was +0.28 ± 0.32 D and +0.50 ± 0.32 D, respectively. The mean UDVA was 0.17 ± 0.13 and 0.15 ± 0.11 logMAR, and the mean CDVA was 0.04 ± 0.10 and 0.04 ± 0.06 logMAR, respectively. The manifest refractive cylinders at 12 months postoperatively were compatible with corneal astigmatism. Conclusions: Implantation of the IOCD resulted in a slight, predicted, and stable hyperopic shift with a low standard deviation. The standard deviation of the prediction error demonstrated excellent refractive accuracy and predictability using the IOCD, which was as low as 0.32 D at the 12-month follow-up.
AB - Background: The marked improvement in cataract surgery and intraocular lens (IOL) quality has led to a decline in posterior capsular opacification (PCO) incidence; however, PCO remains a common complication of cataract surgery. The CleaRing intraocular capsule open device (IOCD) decreases PCO incidence. We aimed to investigate the influence of the CleaRing IOCD on refractive predictability in cataract surgery. Methods: We conducted this prospective pilot study at the Wolfson Medical Center, Holon, Israel. Ten eyes of patients who underwent cataract surgery and insertion of an IOL after IOCD implantation into the capsular bag were included. All patients completed 12 months of follow-up, including refraction, measurement of uncorrected (UDVA) and best-corrected distance visual acuity (CDVA), slit-lamp biomicroscopy, and ultrasound biomicroscopy. Results: All the surgeries were uneventful, with no postoperative complications. The IOL was centred in the device and bag in all cases. The mean prediction error at 1 and 12 months postoperatively was +0.28 ± 0.32 D and +0.50 ± 0.32 D, respectively. The mean UDVA was 0.17 ± 0.13 and 0.15 ± 0.11 logMAR, and the mean CDVA was 0.04 ± 0.10 and 0.04 ± 0.06 logMAR, respectively. The manifest refractive cylinders at 12 months postoperatively were compatible with corneal astigmatism. Conclusions: Implantation of the IOCD resulted in a slight, predicted, and stable hyperopic shift with a low standard deviation. The standard deviation of the prediction error demonstrated excellent refractive accuracy and predictability using the IOCD, which was as low as 0.32 D at the 12-month follow-up.
KW - cataract
KW - open capsule device
KW - posterior capsule opacification
KW - refractive predictability
UR - http://www.scopus.com/inward/record.url?scp=85167418928&partnerID=8YFLogxK
U2 - 10.1111/ceo.14282
DO - 10.1111/ceo.14282
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 37559552
AN - SCOPUS:85167418928
SN - 1442-6404
VL - 51
SP - 685
EP - 691
JO - Clinical and Experimental Ophthalmology
JF - Clinical and Experimental Ophthalmology
IS - 7
ER -