In Silico Evaluation of the Medtronic 780G System While Using the GS3 and Its Calibration-Free Successor, the G4S Sensor

Benyamin Grosman*, Neha Parikh, Anirban Roy, Louis Lintereur, Robert Vigersky, Ohad Cohen, Andrew Rhinehart

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

In silico simulation studies using 5807 virtual patients with insulin dependent diabetes have been conducted to estimate the risk and efficacy with the closed-loop 780G pump when switching between Medtronic Guardian Sensor 3 (GS3) and Medtronic Guardian 4 Sensor (G4S), next generation calibration free glucose sensor. To demonstrate by utilizing a case study that captures the merits of in silico studies with single hormone insulin dependent virtual patients that include variability in pharmacokinetics/pharmacodynamics, age, gender, insulin sensitivity and BMIs. Also, to show that in silico studies can uniquely isolate the effect of a single variable on clinical outcomes. Simulation studies results were compared to clinical and commercial data and were separated by age groups and pump settings. The commercial data, the clinical study data and the simulation studies predicted that switching between GS3 to G4S will introduce a change in glucose average, percentage time between 70 and 180 mg/dL, and percentage time below 70 mg/dL of: 5.2, 3.4, and 3.1 mg/dL, − 1.1, 0.2, and − 1.1%, and − 0.6, − 1.0, and − 0.3%, respectively. We demonstrated that our simulation studies were able to predict the difference in glycemic outcomes when switching between different sensors in real world setting, better than a small clinical controlled study. As predicted, switching between GS3 and G4S sensors with the 780G system does not introduce clinical risk and maintain the clinical outcomes of the sensor. We demonstrated the ability of insulin dependent diabetes virtual patients to predict clinical outcomes and to augment or even replace some small clinical studies.

Original languageEnglish
Pages (from-to)211-224
Number of pages14
JournalAnnals of Biomedical Engineering
Volume51
Issue number1
DOIs
StatePublished - Jan 2023
Externally publishedYes

Keywords

  • Artificial pancreas
  • Diabetes
  • Insulin pump therapy
  • Virtual patients

Fingerprint

Dive into the research topics of 'In Silico Evaluation of the Medtronic 780G System While Using the GS3 and Its Calibration-Free Successor, the G4S Sensor'. Together they form a unique fingerprint.

Cite this