TY - JOUR
T1 - Impact of quadripolar LV leads on heart failure hospitalization rates among patients implanted with CRT-D
T2 - data from the Israeli ICD Registry
AU - on behalf of the Israeli Working Group of Pacing and Electrophysiology
AU - Leshem, Eran
AU - Suleiman, Mahmoud
AU - Laish-Farkash, Avishag
AU - Haim, Moti
AU - Geist, Michael
AU - Luria, David
AU - Glikson, Michael
AU - Goldenberg, Ilan
AU - Michowitz, Yoav
N1 - Publisher Copyright:
© 2017, Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2018/1/1
Y1 - 2018/1/1
N2 - Background: Cardiac resynchronization therapy (CRT) is an effective treatment for heart failure (HF); however, a third of patients are non-responders. The development of quadripolar left ventricular (LV) lead was shown, mainly in single manufactures’ registry, to improve LV remodeling and overall mortality. However, limited reports exist on the impact of quadripolar LV leads on HF hospitalization rates in real-life cohorts. We evaluated the clinical outcomes associated with quadripolar LV leads in a large nation-wide registry including all patients implanted with a cardiac resynchronization therapy with defibrillator (CRT-D). Methods: Between July 2010 and October 2016, 2913 consecutive patients were implanted with a CRT-D and all were prospectively enrolled in the Israeli ICD Registry. Quadripolar LV leads were implanted in 973 (33.4%) patients during this period, and their clinical outcomes were compared to CRT-D recipients implanted with a bipolar LV lead. Primary endpoint was HF hospitalization rate. Results: Quadripolar leads were implanted more in patients with non-ischemic cardiomyopathy and for primary prevention indication and less in post-infarction patients and for secondary prevention of sudden death. Longer QRS duration was observed with quadripolar leads (147 ± 23 vs 143 ± 25; p < 0.001). Outcome event rate for 100 patient years revealed no difference in HF hospitalization rates between bipolar and quadripolar LV leads. Quadripolar lead implant led to lower cardiac mortality, with no influence on overall mortality. Multivariate analysis revealed no significant differences in study endpoints between bipolar and quadripolar LV leads. Conclusion: In a large real-life registry, implantation of quadripolar LV leads in patients with CRT-D did not influence HF hospitalization rates.
AB - Background: Cardiac resynchronization therapy (CRT) is an effective treatment for heart failure (HF); however, a third of patients are non-responders. The development of quadripolar left ventricular (LV) lead was shown, mainly in single manufactures’ registry, to improve LV remodeling and overall mortality. However, limited reports exist on the impact of quadripolar LV leads on HF hospitalization rates in real-life cohorts. We evaluated the clinical outcomes associated with quadripolar LV leads in a large nation-wide registry including all patients implanted with a cardiac resynchronization therapy with defibrillator (CRT-D). Methods: Between July 2010 and October 2016, 2913 consecutive patients were implanted with a CRT-D and all were prospectively enrolled in the Israeli ICD Registry. Quadripolar LV leads were implanted in 973 (33.4%) patients during this period, and their clinical outcomes were compared to CRT-D recipients implanted with a bipolar LV lead. Primary endpoint was HF hospitalization rate. Results: Quadripolar leads were implanted more in patients with non-ischemic cardiomyopathy and for primary prevention indication and less in post-infarction patients and for secondary prevention of sudden death. Longer QRS duration was observed with quadripolar leads (147 ± 23 vs 143 ± 25; p < 0.001). Outcome event rate for 100 patient years revealed no difference in HF hospitalization rates between bipolar and quadripolar LV leads. Quadripolar lead implant led to lower cardiac mortality, with no influence on overall mortality. Multivariate analysis revealed no significant differences in study endpoints between bipolar and quadripolar LV leads. Conclusion: In a large real-life registry, implantation of quadripolar LV leads in patients with CRT-D did not influence HF hospitalization rates.
KW - CRT-D
KW - Heart failure
KW - Hospitalization
KW - Mortality
KW - Quadripolar LV leads
UR - http://www.scopus.com/inward/record.url?scp=85038817308&partnerID=8YFLogxK
U2 - 10.1007/s10840-017-0305-z
DO - 10.1007/s10840-017-0305-z
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:85038817308
SN - 1383-875X
VL - 51
SP - 5
EP - 12
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
IS - 1
ER -