Impact of quadripolar LV leads on heart failure hospitalization rates among patients implanted with CRT-D: data from the Israeli ICD Registry

on behalf of the Israeli Working Group of Pacing and Electrophysiology

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Background: Cardiac resynchronization therapy (CRT) is an effective treatment for heart failure (HF); however, a third of patients are non-responders. The development of quadripolar left ventricular (LV) lead was shown, mainly in single manufactures’ registry, to improve LV remodeling and overall mortality. However, limited reports exist on the impact of quadripolar LV leads on HF hospitalization rates in real-life cohorts. We evaluated the clinical outcomes associated with quadripolar LV leads in a large nation-wide registry including all patients implanted with a cardiac resynchronization therapy with defibrillator (CRT-D). Methods: Between July 2010 and October 2016, 2913 consecutive patients were implanted with a CRT-D and all were prospectively enrolled in the Israeli ICD Registry. Quadripolar LV leads were implanted in 973 (33.4%) patients during this period, and their clinical outcomes were compared to CRT-D recipients implanted with a bipolar LV lead. Primary endpoint was HF hospitalization rate. Results: Quadripolar leads were implanted more in patients with non-ischemic cardiomyopathy and for primary prevention indication and less in post-infarction patients and for secondary prevention of sudden death. Longer QRS duration was observed with quadripolar leads (147 ± 23 vs 143 ± 25; p < 0.001). Outcome event rate for 100 patient years revealed no difference in HF hospitalization rates between bipolar and quadripolar LV leads. Quadripolar lead implant led to lower cardiac mortality, with no influence on overall mortality. Multivariate analysis revealed no significant differences in study endpoints between bipolar and quadripolar LV leads. Conclusion: In a large real-life registry, implantation of quadripolar LV leads in patients with CRT-D did not influence HF hospitalization rates.

Original languageEnglish
Pages (from-to)5-12
Number of pages8
JournalJournal of Interventional Cardiac Electrophysiology
Volume51
Issue number1
DOIs
StatePublished - 1 Jan 2018

Funding

FundersFunder number
Israeli Association for Cardiovascular Trials

    Keywords

    • CRT-D
    • Heart failure
    • Hospitalization
    • Mortality
    • Quadripolar LV leads

    Fingerprint

    Dive into the research topics of 'Impact of quadripolar LV leads on heart failure hospitalization rates among patients implanted with CRT-D: data from the Israeli ICD Registry'. Together they form a unique fingerprint.

    Cite this