Abstract
The closed loop characteristics of a Boost converter were examined for different control schemes. The H∞ control was found to exhibit low output impedance over the widest frequency range. The major disadvantage of this control scheme, as compared to the classical ones, is possible static error due to the lower open loop gain at low frequencies. Good agreement was found between simulation results and experimental measurements.
| Original language | English |
|---|---|
| Pages (from-to) | 1327-1332 |
| Number of pages | 6 |
| Journal | PESC Record - IEEE Annual Power Electronics Specialists Conference |
| Volume | 2 |
| State | Published - 1995 |
| Externally published | Yes |
| Event | Proceedings of the 26th Annual IEEE Power Electronics Specialists Conference. Part 2 (of 2) - Atlanta, GA, USA Duration: 12 Jun 1995 → 15 Jun 1995 |
Fingerprint
Dive into the research topics of 'H∞ control of boost converters: comparison to voltage mode, feedforward and current mode controls'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver