Skip to main navigation Skip to search Skip to main content

Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs continuous subcutaneous insulin infusion

  • Schneider Children's Medicaal Center

Research output: Contribution to journal › Article › peer-review

70 Scopus citations

Abstract

Objective: To compare glycemic patterns by mode of therapy in children with type 1 diabetes mellitus using the Continuous Glucose Monitoring System (CGMS). Design: Open randomized crossover comparing 31/2 months of multiple daily injections (MDI) and continuous subcutaneous insulin infusion (CSII). Setting: Tertiary care, university-affiliated medical center. Patients: Twenty-three children and adolescents with type 1 diabetes mellitus. Interventions. The CGMS was applied for 72 hours after 1 month and at the end of each study arm. Main Outcome Measures: Hemoglobin A1c levels and glucose level profiles were compared between the 2 study arms and the 2 sensor applications for each arm. Results: The arms were similar for mean (SD) hemoglobin A1c levels (CSII, 8.0% [0.8%]; and MDI, 8.2% [0.8%]) and glucose levels. Areas under the curve were significantly larger during MDI for nocturnal and 24-hour hypoglycemia (P=.01 and .04, respectively) and for postprandial hypoglycemia and hyperglycemia (P=.03 and .05, respectively). The rate of hyperglycemia increased during CSII (P=.03), but 24-hour duration and area under the curve for hyperglycemia were similar. Compared with the first CGMS reading in each arm, the second had a longer mean duration of postprandial within-target glucose levels (P=.04), tendency for lower rate of diurnal hypoglycemic events (P=.1), shorter duration of nocturnal hypoglycemia (P=.05), and smaller 24-hour area under the curve for hypoglycemia (P=.04). Conclusions: Intensive treatment with CSII seemed to be associated with slightly better prebreakfast, postprandial, and within-target glucose profiles than MDI, as well as a smaller area under the curve for hypoglycemia. Lower hypoglycemia-related variables in the second sensor reading in each arm indicate that the CGMS may serve as an educational tool to decrease the rate and magnitude of hypoglycemia.

Original languageEnglish
Pages (from-to)677-684
Number of pages8
JournalArchives of Pediatrics and Adolescent Medicine
Volume158
Issue number7
DOIs
StatePublished - Jul 2004

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs continuous subcutaneous insulin infusion'. Together they form a unique fingerprint.

Cite this